(C304CR) Quartz Fluorescence Cuvette, 30 mm Path, 32.4 mL
Original price was: $213.00.$192.00Current price is: $192.00.
C304CR is a JGS1 quartz fluorescence cuvette with a 30 mm optical path, Four-Way Light access and a large 30 × 30 × 45 mm internal chamber. Its open-top body gives direct filling access for methods that use a larger square sample region, and the nominal capacity is 32.4 mL. Sold per 1 cuvette.
Description
C304CR is a JGS1 quartz fluorescence cuvette designed around a 30 mm optical path and a large square sample region. Its Four-Way Light layout and open-top body make it useful when you need side optical access together with straightforward top filling, rinsing and visual checking of the chamber. The nominal capacity is 32.4 mL, with a 30 × 30 × 45 mm internal chamber.
- Path Length
- 30 mm
- Sample Volume (Nominal)
- 32.4 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 30 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 32.4 mL |
| External Dimensions | 34 × 34 × 47 mm |
| Uncapped Cell Dimensions | 34 × 34 × 47 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 47 mm |
| Internal Dimensions | 30 × 30 × 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C304CR when your setup needs a larger fluorescence cell body rather than a narrow chamber. The square internal space gives more room for loading and handling the sample, while the open top leaves the chamber directly accessible from above. This option is also identified with a powder-fused construction term, which is relevant when you are selecting among different cuvette build styles and want to review that construction approach alongside your sample and cleaning routine.
What makes this option different
- The 30 mm optical path suits methods that are set up for a longer beam path through the sample.
- Four-Way Light geometry provides optical access from multiple side faces for fluorescence arrangements that use this beam layout.
- The 30 × 30 × 45 mm internal chamber forms a broad square sample region that is easier to fill and inspect from above than a narrow slot-style cavity.
- The open-top body gives direct pipette or pouring access without a built-in threaded or stoppered closure on the cell body.
- The listed powder-fused construction term distinguishes this version from other joining/build styles in the same general product family, so it should be selected with your method and cleaning approach in mind.
- The uncapped outer size of 34 × 34 × 47 mm is useful for holder and compartment clearance checks.
Using this cell
Fill the cell from the top and keep the measurement orientation consistent if your fluorescence method uses a defined excitation side and collection side. Before placing the cuvette in the instrument, check that the beam will pass through the intended faces and that the sample does not leave visible bubbles or droplets across the light path.
The open chamber is convenient for direct loading, emptying and rinsing. Because this is an open-top body, handle it carefully during transfer and measurement so liquid does not wet the upper rim or spill onto the outer optical faces.
First-use check
Inspect the optical faces, top edge and bottom support area for chips, scratches or particles before first use. Rinse with a suitable liquid for your method, place the cell in its holder, and confirm that it seats stably and presents the intended faces to the beam.
Fit and optical alignment
The uncapped cell body measures 34 × 34 × 47 mm. Use these body dimensions when checking compartment width, holder opening and vertical clearance, especially if your instrument is arranged around a slimmer cuvette format.
Z Height is not specified for this option. If your instrument requires a defined beam-center height, check that point before ordering rather than relying on the overall body height. The listed dimensions apply to the bare open cell body and do not establish installed clearance for any separate cover or accessory.
Solvents and cleaning
This quartz cuvette is listed for fluorescence spectroscopy in the stated 200–2500 nm range. For general background on cuvette construction approaches, see Compare fabrication options.
The source identifies this item with a powder-fused construction term. That helps distinguish the build style of this exact option, but it does not by itself establish a full chemical-resistance list for every solvent or cleaning condition. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical access, closures, connections and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions that matter to your holder and measurement geometry. Discuss your requirements and quote part number C304CR.
Additional information
| Weight | 100 g |
|---|