(C054CS) Quartz Fluorescence Cuvette, 5 mm Path, 875 µL
Original price was: $156.00.$141.00Current price is: $141.00.
C054CS is a JGS1 quartz fluorescence cuvette with a 5 mm optical path, Four-Way Light access and an 875 µL nominal capacity. Its black-wall, open-top body combines a compact 5 × 5 mm internal cross-section with a 12.5 × 12.5 × 45 mm uncapped format for fluorescence work that uses a smaller sample chamber and light-shielding around the sample region. Supplied as 1 cuvette.
Description
C054CS is a JGS1 quartz fluorescence cuvette with a 5 mm optical path, a black-wall body and Four-Way Light access. Its compact 5 × 5 mm internal cross-section and 875 µL nominal capacity make it a practical choice when you want a smaller fluorescence sample chamber, while the open top keeps filling and rinsing straightforward. This listing is for 1 cuvette.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 875 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 5 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 875 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Internal Dimensions | 5 × 5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
Choose this option
Choose C054CS when your method uses a 5 mm path and you want a compact fluorescence cell with light-shielding around the sample region. The Four-Way Light layout is useful for fluorescence beam arrangements that rely on side optical access as well as the main path, and the open-top body suits routine pipetting, rinsing and inspection between runs.
What makes this option different
- 5 mm optical path for fluorescence methods specified around this path length.
- Four-Way Light geometry, giving optical access through more than one face for fluorescence setups that use side access in addition to the main beam path.
- Black-wall body for light-shielding use around the sample region.
- 5 × 5 mm internal cross-section with 875 µL nominal capacity for a compact sample chamber.
- Open-top format for direct filling and rinsing.
- Standard 80 adhesive-bonded quartz construction.
Using this cell
Fill the cell from the top and keep the same orientation for blanks and samples so the optical geometry remains consistent. Because the chamber is compact, inspect the beam region carefully and remove bubbles or droplets before measurement.
The stated 875 µL value is a nominal capacity, not a minimum working volume. The listed 5 × 5 mm internal dimensions describe the chamber cross-section, so if you plan to work at low fill levels, make sure the liquid level covers the measurement region in your instrument.
First-use check
- Inspect the optical faces, top opening and body edges for chips, dust or scratches.
- Rinse before first use with a cleaning liquid suitable for your method.
- Place the cuvette in the holder and verify orientation through the intended optical faces.
- Run a blank in the same orientation planned for sample measurements.
Fit and optical alignment
The uncapped outer dimensions are 12.5 × 12.5 × 45 mm, with a 12.5 × 12.5 mm base. Use those dimensions to check holder fit, seating and clearance around the body.
This is an open-top cell, so plan for use as an open cuvette unless your setup provides its own compatible cover arrangement. Four-Way Light indicates multi-face optical access, not universal instrument compatibility. If your instrument depends on a defined beam-center height, note that Z Height is not established for this SKU and should be checked separately.
Solvents and cleaning
Standard 80 is the MQ option for routine water-based samples and buffers at room temperature. In this SKU, that corresponds to an adhesive-bonded quartz construction, so it is better suited to water-based work than to organic sample solvents or organic cleaning agents. If your method involves organic solvents, ask about a more suitable sintered or molded quartz alternative.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue and avoid leaving dried residue in the chamber.
Included with this option
Price is for 1 cuvette, supplied as the listed C054CS specification.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, wavelength range, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements and mention part number C054CS.
Design notes for this configuration: 5 mm Black-Wall Quartz Cuvette: Arranging Excitation and Collection
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.