(C054CR) Quartz Fluorescence Cuvette, 5 mm Path, 800 µL
Original price was: $109.00.$99.00Current price is: $99.00.
C054CR is a JGS1 quartz fluorescence cuvette with a 5 mm optical path, Four-Way Light access and an open-top 5 × 5 mm chamber. Its 800 µL nominal capacity and direct top access make it suitable for methods that need straightforward filling and visual inspection from above. Sold individually as 1 cuvette per listed price unit.
Description
C054CR is a quartz fluorescence cuvette for methods built around a 5 mm optical path and side optical access. Its open-top body and 5 × 5 mm internal chamber let you fill, rinse and inspect the sample region directly from above, while the 800 µL nominal capacity gives a defined chamber size for routine handling. This is a single cuvette sale unit in JGS1 quartz.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 800 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 800 µL |
| External Dimensions | 7.5 × 7.5 × 45 mm |
| Uncapped Cell Dimensions | 7.5 × 7.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Internal Dimensions | 5 × 5 × 43.75 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C054CR when you need a compact fluorescence cell with direct top loading and a 5 mm path. The Four-Way Light layout suits measurement setups that use side optical access, and the square open chamber is easy to reach with a pipette for filling, emptying and cleaning between runs.
What makes this option different
- Open-top cell body for direct access to the sample chamber during filling, rinsing and visual inspection.
- 5 mm optical path for methods specified around this nominal path length rather than a longer standard cell path.
- Four-Way Light geometry for side optical access in fluorescence setups with compatible beam arrangement.
- 5 × 5 mm internal chamber section, giving a square sample region that is straightforward to load from above.
- 800 µL nominal capacity matched to this exact chamber format; this is a nominal cell volume, not a minimum working fill.
- Powder-fused supplier construction term, a relevant choice when you are reviewing how the cell body is made alongside chamber access and cleaning routine.
Using this cell
Fill the chamber from the top, then check that the liquid cleanly covers the part of the sample region used by your measurement. The open chamber makes it easier to see bubbles, droplets on the walls or remaining residue before you place the cell in the holder.
Keep the same orientation for blank and sample measurements so the excitation and collection directions stay consistent in your setup. The 800 µL figure is the nominal cell capacity; if your method depends on a specific liquid height, confirm that your filled sample covers the required optical region in use.
First-use check
Inspect the optical faces and the open chamber for dust, chips, residue or scratches before first use. Rinse with a suitable cleaning liquid for your method, fill a blank, and confirm that no bubbles or droplets remain in the intended optical region.
Fit and optical alignment
The uncapped cell body measures 7.5 × 7.5 × 45 mm. These dimensions are useful for checking holder clearance around the bare cell and for making sure you have enough access above the opening for pipetting and cleaning.
The internal dimensions are 5 × 5 × 43.75 mm, which helps you judge the shape of the sample chamber and how you will approach it from above. Z Height is not stated for this item, so any instrument or accessory that relies on a fixed beam-center height should be checked separately before routine use.
Solvents and cleaning
This cuvette is described for this SKU with the supplier term powder-fused construction. In practical use, that construction detail is most relevant when you are choosing among cell-making methods alongside the open-top geometry, sample type and cleaning routine. For general background on cuvette construction options, see the fabrication guide.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe optical faces gently with non-abrasive optical tissue. Chemical compatibility limits for this exact assembly are not established here, so aggressive chemicals, elevated temperature or long contact times should be checked for suitability before use.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, and tolerance requirements. Send your drawing or labelled sketch together with holder or instrument details, the critical dimensions for your setup, sample conditions and target quantity. Discuss your requirements and mention part number C054CR.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.