(C104SR4) Quartz Micro Cuvette, 10 mm / 3 mm (dual path) Path, 1.05 mL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR4 is a JGS1 quartz micro cuvette that combines a 10 mm primary path with a 3 mm secondary path in the same Four-Way Light body. This research-style option uses the supplier-described fused integrated construction and offers 1.05 mL nominal capacity for UV/Vis work that needs two optical path choices in one compact cell. Supplied as 1 cuvette per sale, with a closure included.
Description
C104SR4 is a JGS1 quartz micro cuvette with a 10 mm primary path, a 3 mm secondary path and Four-Way Light optical access in one compact body. That combination lets you work with a standard path and a shorter cross-path in the same cell, while the supplier-described fused integrated construction and included closure suit a research-style cell that is filled from the top and then closed for handling. The nominal capacity is 1.05 mL, and the stated wavelength range is 200–2500 nm.
- Path Length
- 10 mm / 3 mm (dual path)
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 3 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 3 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 3 mm |
Choose this option
Choose C104SR4 when you want two defined optical paths in one cuvette rather than switching between separate cells. It is useful for methods that need a standard 10 mm read direction plus a shorter 3 mm read direction, with side access available for compatible optical geometry. The compact 12.5 × 12.5 mm body also helps when holder space is limited and you want to keep the same sample in place while changing the measurement direction.
What makes this option different
- Dual-path cell body: the cuvette provides both a 10 mm primary path and a 3 mm secondary path in the same sample cell.
- Four-Way Light layout: optical access from four sides supports setups that use more than one beam direction or side observation geometry.
- Fused integrated construction: the supplier describes this research-style version as fused integrated, which is a useful distinction if you are specifically choosing among different construction approaches for the same general cell format.
- Compact micro footprint: the uncapped cell body is 12.5 × 12.5 × 45 mm, helping you plan holder fit and top clearance.
- 1.05 mL nominal capacity: this gives a small cell format without implying a minimum working volume.
- Closure included: this option includes a closure for the single cuvette sold here.
Using this cell
Fill from the top opening and make sure the illuminated sample region is fully covered for the path you intend to use. If your method uses both optical directions, keep the cuvette orientation consistent so the same faces and path directions are used for blank and sample measurements.
After filling, fit the included closure gently for routine handling. The nominal 1.05 mL figure describes the cell capacity, not the minimum volume needed for every instrument or beam position.
First-use check
- Inspect the optical faces, opening and closure for chips, dust or residue.
- Test the cell in your holder before preparing samples.
- Verify that the beam passes through the intended optical path in your chosen orientation.
Fit and optical alignment
The uncapped outer dimensions are 12.5 × 12.5 × 45 mm. Use those body dimensions to check holder seating, side clearance and the space available above the cell once the closure is fitted.
The Four-Way Light arrangement and the stated 3 mm sample-region width are relevant when planning beam direction and coverage through the narrower path. Z Height is not specified for this item, so any instrument or accessory that depends on a fixed beam-center height should be checked against your holder geometry before ordering.
Solvents and cleaning
Choose cleaning and sample-contact conditions that suit your actual method and the complete assembled cell. The supplier description for this variant highlights a research-style fused integrated construction, but that does not replace checking suitability for your own chemicals, temperature and contact time when those conditions are demanding.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe optical faces with non-abrasive optical tissue. For general fabrication background, see Compare fabrication options.
Included with this option
Supplied as 1 cuvette per sale. A stopper is included with this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, path arrangement, capacity or holder fit, send your drawing or labelled sketch together with your instrument or holder details. We can also review beam position, sample conditions and quantity requirements. Use part number C104SR4 when you discuss your requirements.