(C504CA1) Quartz Fluorescence Cuvette, 10 mm / 50 mm (dual path) Path, 17.5 mL
Original price was: $474.00.$427.00Current price is: $427.00.
C504CA1 is a JGS1 quartz fluorescence cuvette with a 10 mm / 50 mm dual-path layout, Four-Way Light access and 17.5 mL nominal capacity. The open-top design suits direct filling and methods that use a longer optical direction in the same cell body. Sold as 1 cuvette per listed price unit, with closure included.
Description
C504CA1 is a JGS1 quartz fluorescence cuvette for fluorescence spectroscopy with two optical directions in one body: 10 mm on one axis and 50 mm on the other. Its Four-Way Light layout and 17.5 mL nominal capacity make it a practical choice when your method needs side optical access and a longer path through a larger sample volume.
The open top gives direct access for filling, rinsing and inspection before measurement. Closure is included, but this product should be selected for its optical layout and sample access rather than for sealed or pressure-handling use.
- Path Length
- 10 mm / 50 mm (dual path)
- Sample Volume (Nominal)
- 17.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm / 50 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 12.5 × 52.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 52.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C504CA1 when your setup needs a 50 mm optical direction without giving up a 10 mm cross-axis in the same cuvette. This format is useful when the measurement geometry matters as much as the path length, especially in fluorescence work where side access and orientation inside the holder need to be planned together. The 17.5 mL nominal capacity also suits methods that already work with millilitre-scale fills rather than trace volumes.
What makes this option different
- 10 mm / 50 mm dual-path geometry provides two defined optical directions in one cuvette body.
- Four-Way Light configuration gives optical access from multiple faces around the sample region.
- Open-top construction allows direct filling, rinsing and visual inspection from above.
- 17.5 mL nominal capacity fits larger sample fills than small-volume fluorescence cells.
- JGS1 quartz body supports the stated 200–2500 nm wavelength range for this option.
Using this cell
Fill from the top opening and place the cuvette so the required optical direction faces the instrument beam path. Keep the same orientation for blank and sample measurements, especially when switching between the 10 mm and 50 mm directions is part of the method.
Before reading, check that the beam area is free of bubbles, droplets and residue on the optical faces. If you use the included closure during handling between steps, do not treat it as a pressure-rated or leak-tested sealing system.
First-use check
Inspect the optical faces, edges and top opening for chips, residue or transport damage before first use. Rinse appropriately for your method, insert the cell squarely, and verify that the intended optical direction is aligned as planned.
Fit and optical alignment
The stated 12.5 × 52.5 × 45 mm dimensions apply to the uncapped cell body. Because this is a long rectangular format rather than a standard square cuvette shape, check holder seating, side clearance and beam access in your instrument before ordering.
Z Height is not established for this listing. If your instrument has a fixed beam center or tight holder geometry, confirm the required beam height and clearance instead of relying on the outer body size alone.
Solvents and cleaning
This cuvette uses a supplier-described fused integrated construction. For general background on MQ cuvette fabrication options, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with suitable non-abrasive lab or optical wipes.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for changes to dimensions, optical path length, sample volume, optical access, closures and related fit requirements. If you need a different geometry, send a dimensioned drawing or labelled sketch together with holder details and your application requirements via this contact page, and mention part number C504CA1.
Additional information
| Weight | 100 g |
|---|