(C022CR5) Quartz Demountable Cuvette, 2 mm Path, 600 µL
Original price was: $294.00.$265.00Current price is: $265.00.
C022CR5 is a JGS1 quartz demountable cuvette supplied as a 2 mm path cell with a removable quartz cover plate and matching holder. Its 600 µL nominal capacity and rounded-end sample groove suit fluorescence spectroscopy setups that benefit from direct access during loading, inspection and cleaning. Sold per 1 cuvette-and-holder option for the listed price unit.
Description
C022CR5 combines a 2 mm path JGS1 quartz demountable cell with a removable quartz cover plate and an included holder. Its 600 µL nominal capacity and rounded-end sample groove give you open access to the sample region before assembly, which is useful when the sample needs careful placement, visual inspection or thorough cleaning between fluorescence measurements.
This option is supplied as a supported cell arrangement rather than the cell body alone. That helps when you want the demountable sample area and the handling support in the same purchase, while keeping the chamber accessible during preparation.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 600 µL
- Closure Type
- Removable Cover Plate
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Demountable Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 600 µL |
| External Dimensions | 45 × 12.5 × 4.5 mm |
| Overall Dimensions with Closure | 45 × 12.5 × 4.5 mm |
| External Dimensions Scope | With Closure |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Removable Cover Plate |
| Closure Material | Quartz |
| Closure Included | Yes |
| Holder Included | Yes |
| Slot Depth | 2 mm |
Choose this option
Choose C022CR5 when you want the 2 mm demountable cell and holder together, with a removable quartz cover plate over a rounded-end sample groove. This layout suits methods where you load directly into the groove, check the wetted area before measurement, and prefer to move the assembled cell in a holder rather than sourcing the support separately.
What makes this option different
- 2 mm optical path with 600 µL nominal capacity.
- Rounded-end sample groove for direct loading into an open sample region before the cover plate is seated.
- Removable quartz cover plate included.
- Holder included with this sales option.
Using this cell
Load the sample into the groove, then place the quartz cover plate evenly before positioning the cell in the holder. The demountable format gives access to the sample region during preparation, so you can inspect coverage and remove visible residue before measurement.
For routine work, keep the same orientation for blank and sample runs. Check the groove and optical faces for bubbles, dust, smears or particles before inserting the assembled cell into your instrument setup.
First-use check
- Inspect the cover plate, cell body and holder for dust, chips or handling residue.
- Assemble the cover plate without forcing it into place.
- Run a blank to confirm clear optical access and stable seating in the holder.
Fit and optical alignment
The stated 45 × 12.5 × 4.5 mm dimensions apply to the covered cell body with the cover plate in place. They do not define the full installed envelope of the holder, so fixture and compartment clearance should be checked for the holder-and-cell assembly rather than from cell-body size alone.
Z Height is not stated for this option. If your fluorescence setup depends on a defined beam-center height or a specific holder position, check that geometry against your instrument or fixture before ordering.
Solvents and cleaning
Choose sample and cleaning conditions for the complete assembly, including the quartz body, quartz cover plate and holder contact areas where relevant. If your method involves organic solvents, aggressive reagents, elevated temperature or long contact times, check suitability before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean optical faces and contact surfaces gently with non-abrasive optical tissue or similar lab wipes, and dry the mating surfaces before reassembly.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and holder-related fit. Send a dimensioned drawing or labelled sketch together with your instrument or fixture details, sample conditions and quantity. Discuss your requirements and mention part number C022CR5.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews