C012CS8 is a JGS1 quartz Large-Window Cuvette with a 1 mm optical path, Two-Way Light transmission and an open top for direct filling from above. Its broad-face body and 1.5 mL nominal capacity suit short-path transmission work where sample access and holder clearance both matter. The listed price unit covers 1 cuvette.
Description
C012CS8 is a JGS1 quartz Large-Window Cuvette for short-path transmission measurements with a 1 mm optical path and 1.5 mL nominal capacity. The open-top body gives direct access to the sample region for filling, inspection and rinsing from above, while the broad opposing faces support a straightforward Two-Way Light optical layout. The listed price unit covers 1 cuvette.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 1.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.5 mL |
| External Dimensions | 3 × 38 × 50 mm |
| Cell Body Dimensions | 3 × 38 × 50 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top |
Choose this option
Choose C012CS8 when you need a short 1 mm path in a large-window body rather than a narrow micro-style format. This geometry is useful when you want direct top access to the chamber and enough face area to position the cell carefully in a holder, while still working with a nominal 1.5 mL sample volume.
What makes this option different
- Open-top access lets you fill, inspect and rinse the sample chamber directly from above without working through a cap or tubing connection.
- 1 mm optical path suits methods that require a short transmission path instead of a standard longer cell.
- Large-window body provides broad opposing optical faces, which can be easier to position in holders that need clearance across the main beam faces.
- Two-Way Light layout supports transmission through the opposing faces without implying side-window or bottom-window access.
- 1.5 mL nominal capacity gives a defined chamber size for planning filling and rinsing, while remaining an open cell rather than a sealed assembly.
- Fused integrated construction is the supplier’s joining term for this exact SKU; in ordinary use, it means you select it as an assembled quartz cell body for direct filling and careful rinsing, not as a demountable plate-style cell.
Using this cell
Fill the cell from the top and handle it by non-optical areas whenever possible. Add liquid carefully so the beam path is free of bubbles, and keep the same orientation for blank and sample measurements if your method depends on consistent positioning.
The 1.5 mL figure is a nominal cell volume, not a minimum working volume. If you plan to run below a full fill, check that your actual liquid height will still cover the beam in your instrument.
First-use check
- Inspect the optical faces and chamber opening for chips, residue or transit marks.
- Check that your holder accepts the body-only geometry and leaves enough clearance at the open top for filling.
- Run a blank in the intended orientation and verify beam alignment before preparing a full sample.
Fit and optical alignment
The listed body dimensions are 3 × 38 × 50 mm in the original source order, and they apply to the body only. Use these dimensions to check holder clearance, insertion space and access around the broad optical faces.
Z Height is not established for this SKU. If your spectrometer or holder has a fixed beam center, body size alone does not confirm alignment, so beam position should be checked before purchase or first use.
Solvents and cleaning
This cell has a quartz body, but detailed chemical limits for this exact SKU are not established here. Review your actual sample, rinse and cleaning conditions if they involve demanding chemicals, elevated temperature or long contact time.
The supplier describes this cell as fused integrated construction, so ordinary care still matters at joined, assembled-cell level: rinse promptly after use, avoid dried residue in the chamber, and use gentle cleaning methods suited to assembled quartz cells. Compare fabrication options if you are selecting among different sample and cleaning routines.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, construction approach and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; final feasibility, quantity, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C012CS8.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.