(C502CE3) Quartz Large-Window Cuvette, 10 mm Path, 17.5 mL
Original price was: $171.00.$154.00Current price is: $154.00.
C502CE3 is a JGS1 quartz large-window cuvette with a 10 mm optical path, Two-Way Light transmission layout and 17.5 mL nominal capacity. Its open-top body gives direct access for filling, rinsing and visual checking before measurement. Sold as 1 cuvette per price unit, with a closure included.
Description
C502CE3 is a JGS1 quartz large-window cuvette built around a standard 10 mm optical path in a larger 17.5 mL body. The open-top design gives direct access to the sample chamber for filling, rinsing and inspection, which is useful when you want a broader cell format rather than a narrower small-body cuvette. It is intended for Two-Way Light transmission use across the stated 200–2500 nm range.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 17.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 52.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 52.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C502CE3 when your method uses a 10 mm transmission path but you want a larger nominal sample capacity and easier top access during handling. The large-window body format is the key practical difference here: it gives more room for manual filling and cleaning while keeping the familiar straight-through optical path.
What makes this option different
- 10 mm optical path for standard transmission measurement geometry.
- Two-Way Light layout for beam entry and exit through the opposing transmission faces.
- 17.5 mL nominal capacity in a larger-body cuvette for methods that use a higher fill volume.
- Open-top access so you can fill, rinse and inspect the chamber directly from above.
- JGS1 quartz construction for the stated 200–2500 nm wavelength range.
- Supplier-described fused integrated construction as the supplier’s joining/construction term for this cell.
Using this cell
Fill the cuvette from the top, then place it so the beam passes through the two transmission faces along the 10 mm path. The open top makes it easier to add sample carefully, check for visible bubbles and rinse the chamber between runs.
The 17.5 mL figure is the nominal capacity of the cell, not a minimum working volume. If your method uses a partial fill or depends on a fixed beam position, check that the liquid level fully covers the beam in your own setup.
First-use check
Before first use, inspect the optical faces and edges for dust, fingerprints or transit damage. Test the empty cell in the holder first, then run a blank at your working wavelength to confirm orientation and baseline before introducing sample.
Fit and optical alignment
The body dimensions are 52.5 × 12.5 × 45 mm. This larger-body format is an important installation point, so check holder width, depth and chamber clearance if your instrument is arranged around a more compact cuvette size.
Z Height is not specified for this option. If your instrument has a fixed beam height, confirm that requirement directly instead of relying on the outer body size alone.
Solvents and cleaning
This cell is made from quartz. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis or abrasive cleaning methods that can damage the optical surfaces.
Detailed chemical limits for this exact option are not established here. If your sample, rinse solvent or cleaning routine involves aggressive chemicals, elevated temperature or long contact time, review those conditions before ordering. For general MQ construction background, see fabrication options.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for changes involving dimensions, optical path length, sample volume, optical windows, Z Height, closures, connections and tolerance requirements. Send a dimensioned drawing or labelled sketch together with your holder details, wavelength range, sample chemistry and quantity. Discuss your requirements and mention part number C502CE3.
Additional information
| Weight | 100 g |
|---|