(C504CA4) Quartz Fluorescence Cuvette, 50 mm / 10 mm (dual path) Path, 17.5 mL
Original price was: $237.00.$214.00Current price is: $214.00.
C504CA4 is a JGS1 quartz fluorescence cuvette with a 50 mm primary path, a 10 mm secondary path and a four-way light body for multi-direction optical access. Its 17.5 mL nominal capacity suits methods that work with a larger filled sample region rather than micro-volume layouts. Supplied as 1 cuvette with a lid.
Description
C504CA4 is a JGS1 quartz fluorescence cuvette for setups that need a long 50 mm optical path in the main measurement direction while keeping a 10 mm secondary path in the same cell body. Its four-way light layout gives optical access from multiple sides, and the 17.5 mL nominal capacity suits methods built around a larger filled sample region. This listing is for 1 cuvette with a lid.
- Path Length
- 50 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 17.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 50 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 12.5 × 52.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 52.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C504CA4 when your method is arranged around a long optical distance and a four-side optical body. The 50 mm primary path is the key selection point, while the 10 mm secondary path gives an additional defined optical direction in the same cuvette. This combination is useful when you need a longer main path but still want side access for fluorescence excitation or collection planning.
What makes this option different
- 50 mm primary path: intended for methods that require a longer measurement path through the sample.
- 10 mm secondary path: adds a second specified optical direction in the same body.
- Four-way light body: gives optical access from multiple sides for fluorescence layouts with compatible beam geometry.
- 17.5 mL nominal capacity: suited to millilitre-scale filling rather than micro-volume use.
- JGS1 quartz construction: appropriate for the stated optical range of 200-2500 nm.
Using this cell
Fill the cell from the top and place the lid before measurement if your procedure calls for covered handling. Keep the optical faces clean, and use the same orientation for blank and sample measurements so the selected path and side-access geometry stay consistent.
Check the sample region for bubbles, droplets and residue before reading, especially when using the 50 mm path. The nominal volume describes the cell capacity, not a minimum working fill, so make sure your actual fill level covers the optical region required by your setup.
First-use check
- Inspect the optical faces, edges and top opening for shipping damage or residue.
- Test the uncapped body in your holder and confirm that side access remains clear in the intended orientation.
- Run a blank and verify clean beam passage through the path direction you plan to use.
Fit and optical alignment
The listed outer dimensions apply to the uncapped cell body: 12.5 × 52.5 × 45 mm. Use these dimensions when checking holder space, side optical access and top clearance around the body itself.
Z Height is not listed here, so instrument fit should not be judged from body size alone. If your holder or fluorescence optics depend on a specific beam-center height, check that alignment before ordering.
Solvents and cleaning
This is a quartz cuvette body. For a general guide to cuvette construction approaches, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. After use, rinse promptly with a suitable solvent for your method and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 fluorescence cuvette with a lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can discuss related JGS1 quartz versions for changes to dimensions, path length, sample volume, optical access or closure arrangement. Send a labelled sketch or drawing together with holder details, wavelength range and sample conditions via our contact page, and refer to C504CA4.