(C202CA6) Quartz Standard Cuvette, 20 mm Path, 7 mL, Pack of 2
Original price was: $57.00.$52.00Current price is: $52.00.
C202CA6 is a pack of 2 JGS1 quartz standard cuvettes for UV/Vis spectroscopy, each with a 20 mm optical path, Two-Way Light layout and 7 mL nominal capacity. The open-top body allows direct filling, and PTFE lids are included. Sold as 2 cuvettes per listed price unit.
Description
C202CA6 is a JGS1 quartz standard cuvette set for UV/Vis work that uses a 20 mm optical path. Each cuvette combines a Two-Way Light layout with a 7 mL nominal capacity in an open-top rectangular body, making this option useful when you want a ready pair for blank-and-sample work or duplicate preparation within one purchase. PTFE lids are included for covered handling after filling.
- Path Length
- 20 mm
- Sample Volume (Nominal)
- 7 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 20 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 7 mL |
| External Dimensions | 12.5 × 22.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 22.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C202CA6 when you need this 20 mm path specification as a confirmed two-cuvette sale unit. The open top keeps filling and rinsing straightforward, while the matched sale quantity is convenient when your workflow uses one cuvette for a blank and one for the sample, or when you want a spare of the same listed specification on hand. The 7 mL nominal capacity suits routine standard-cell handling without moving to a smaller-volume format.
What makes this option different
- Pack of 2 cuvettes per listed price unit.
- 20 mm optical path for UV/Vis methods built around this longer absorbance path.
- Two-Way Light configuration for beam transmission through two opposing optical faces.
- Open-top access for direct filling, pipetting and visual checking of the sample chamber.
- PTFE lids included for covering the cells during normal bench handling.
- 7 mL nominal capacity per cuvette for standard sample loading in this body size.
Using this cell
Fill each cuvette from the top and make sure the liquid covers the beam area used by your instrument. Keep the orientation consistent across blank and sample measurements, and remove visible bubbles before reading.
The included lids cover the open tops during normal use, but this is not a pressure-rated or leak-tight assembly. The stated 7 mL is a nominal capacity for each cuvette and should not be used as a minimum working volume for beam coverage.
First-use check
- Inspect both cuvettes for residue, dust or handling marks on the optical faces.
- Seat each empty cell in the holder before preparing your measurement pair.
- Run a blank in the same orientation planned for sample measurement.
- After filling, confirm that the sample region is bubble-free and fully covers the beam.
Fit and optical alignment
The uncapped dimensions of each cuvette are 12.5 × 22.5 × 45 mm. These values describe the bare cell body, so they are useful for checking holder seating and general body clearance, while top clearance for the installed lid should be checked separately if space is limited.
Z Height is not established for this SKU. If your instrument requires a specific beam-center height, confirm that alignment before ordering rather than relying on the standard body shape alone.
Solvents and cleaning
These cuvettes are described for contact with acids, alkalis and organic liquids, but that statement does not define concentration, temperature, exposure time or full compatibility for every contacting component. If your method involves strong chemicals, elevated temperature or liquid contact with the lid area, review the exact conditions before routine use.
For fabrication background, see MQ Cuvette Fabrication Glossary. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
Pack of 2 quartz cuvettes with PTFE lids.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for changes to dimensions, optical path length, sample volume, windows or Z Height, closures and fabrication requirements. Send a dimensioned drawing or labelled sketch together with your holder details, measurement wavelength, sample conditions and target quantity through our contact page, and quote part number C202CA6.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.