(C104SE8) Quartz Stoppered Cuvette, 10 mm Path, Pack of 2
Original price was: $320.00.$288.00Current price is: $288.00.
C104SE8 is a quartz stoppered cuvette with a 10 mm optical path and Four-Way Light geometry. The included PTFE stopper gives you a covered sample opening after filling, and the four-side optical access suits methods that need more than a two-face transmission layout. Supplied as a pack of 2 cuvettes.
Description
C104SE8 is a quartz stoppered cuvette for methods that use a 10 mm optical path and need optical access from four sides of the cell body. The PTFE stopper lets you fill the sample chamber from the top and then cover the opening for routine handling, while the Four-Way Light layout suits setups that use the main beam direction together with side optical access. This MQ listing is supplied as a pack of 2 cuvettes.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 3.5 mL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Material | PTFE |
| Closure Included | Yes |
Choose this option
Choose C104SE8 when your method needs four-side optical access in a stoppered quartz cell, and when a two-cuvette purchase better matches your workflow. This format is useful when you want direct top filling followed by a covered opening, and when side optical access matters as well as the main 10 mm transmission path. The two-piece sale unit can also suit paired routine work such as blank-and-sample preparation or keeping a matching spare in the same order.
What makes this option different
- Four-Way Light geometry: optical access is available from four sides of the cuvette body.
- 10 mm path length: suitable for methods specified for a 10 mm optical path.
- Stoppered opening: the sample is loaded from the top and covered with an included PTFE stopper.
- Quartz body: suited to optical cell use where quartz is required by the method.
- Pack of 2: the MQ priced sale unit for this listing is two cuvettes.
Using this cell
Fill each cell from the top so the liquid level covers the beam region used by your instrument, then seat the stopper gently. If your setup uses side optical access as well as the main beam direction, keep the cuvette orientation consistent between blank and sample runs.
Handle the cuvettes by the non-optical surfaces and check for bubbles or droplets in the reading area before measurement. When using both cells in one workflow, prepare and orient them consistently so handling differences do not become part of the method.
First-use check
Inspect both cuvettes and both stoppers for chips, particles or handling residue before first use. Rinse with a suitable liquid for your method, place a blank in the holder, and confirm beam coverage and orientation before running valuable samples.
Fit and optical alignment
Four-side optical access is useful for methods that do more than simple two-face transmission, but it does not by itself establish fit for any specific instrument. The external dimensions and Z Height are not established here, so holder clearance and beam position should be checked where instrument geometry is critical.
The stopper covers the opening during routine handling, but this product should not be treated as a pressure-rated, leak-tested or closed-circuit assembly. If your application involves inversion, transport while filled or other demanding handling conditions, review those requirements separately.
Solvents and cleaning
The cuvette body is quartz and the closure is PTFE. The exact chemical limits of the assembled cell are not established here, so if your sample or cleaning routine involves aggressive chemicals, extended contact time or elevated temperature, check suitability for the complete cuvette-and-stopper arrangement before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces with non-abrasive optical tissue or another suitable non-scratching material. For general fabrication guidance, see https://machinedquartz.com/fabrication-method-of-cuvettes/.
Included with this option
Supplied as 2 cuvettes in the current MQ sale unit. PTFE stopper closure is included. No additional accessories are specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom quartz cuvette requirements involving dimensions, path length, optical access, closures or holder-related fit. Send your holder or instrument details, critical dimensions, sample conditions and required quantity at https://machinedquartz.com/contact/ and reference C104SE8.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.