(C402CR5) Glass Standard Cuvette, 40 mm Path, 14 mL
Original price was: $100.00.$90.00Current price is: $90.00.
C402CR5 is a glass standard cuvette for visible absorbance measurements with a 40 mm optical path, a Two-Way Light layout and a 14 mL nominal capacity. Its open-top format gives direct access for filling and emptying, with no closure included.
Description
C402CR5 is a glass standard cuvette for visible absorbance work that uses a 40 mm optical path in an open-top cell body. Its 14 mL nominal capacity and straight-through Two-Way Light layout make it a practical choice when your method is built around a longer path and direct top access for filling, rinsing or emptying.
This option is intended for visible-range measurements and is listed for 350–2000 nm use. The open top keeps sample access simple, but it also means you should select it for workflows that do not require a supplied cap or other closure.
- Path Length
- 40 mm
- Sample Volume (Nominal)
- 14 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Path Length | 40 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 14 mL |
| External Dimensions | 42.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 42.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | No |
| Opening Configuration | Open Top |
Choose this option
Choose C402CR5 when your method specifically requires a 40 mm light path rather than the more common shorter-path cuvette geometry. The longer path is the key selection point here, and the 14 mL nominal capacity helps you plan the sample volume needed for that cell format. The open-top design also suits bench workflows where you fill, inspect and rinse the cell directly from above.
What makes this option different
- 40 mm optical path for methods set up around a long straight-through measurement path.
- Open-top access for direct filling, emptying and visual checking of the sample chamber from above.
- Two-Way Light layout for transmission measurements across the defined path, rather than side-access optical arrangements.
- 14 mL nominal capacity that matches this longer-path standard-cell format.
- Visible-range use with a listed wavelength range of 350–2000 nm.
- No closure included, so any covering method must be planned separately if your procedure needs one.
Using this cell
Fill the cell from the top and make sure the liquid level covers the instrument beam during measurement. Because the stated 14 mL figure is a nominal capacity, it should not be treated as a minimum working fill. If your method uses a limited sample volume, check beam height and fill level in your own setup before routine use.
For consistent readings, keep the same cell orientation for blank and sample, and remove visible bubbles before measurement. Handle the cuvette by the outer non-optical surfaces where possible to keep the light path clean.
First-use check
Before first use, inspect the rim and optical faces for dust, chips or handling marks. Rinse with a liquid suitable for your method, then place the cell in the holder to confirm stable seating and correct beam passage through the intended optical faces.
Fit and optical alignment
The recorded outer dimensions apply to the uncapped cell body: 42.5 × 12.5 × 45 mm. Use these uncapped dimensions when checking holder width, depth and top clearance, especially if your instrument area is tight or normally accommodates a capped cell profile.
This is a Two-Way Light cuvette for straight-through measurement across the 40 mm path. Z Height is not specified for this exact option, so instruments or holders with a fixed beam-height requirement should be checked before ordering.
Solvents and cleaning
The supplier describes a fused integrated glass construction. Rinse through the open top and select sample and cleaning liquids for the complete glass cell. This visible-absorbance option has no accompanying closure, so filling and cleaning access remain through the uncovered opening.
For aggressive chemicals, mixed solvents, elevated temperature or extended contact time, check suitability for your actual exposure conditions before use. Use non-abrasive cleaning methods and avoid scratching the optical faces. See fabrication options when discussing a different sample or cleaning requirement.
Included with this option
Open-top glass cuvette body with no closure included. The customer sale quantity for this listing should be checked with us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, optical path, sample volume, opening style or a quartz version for a modified design, we can review a custom project. Send your drawing or labelled sketch, instrument or holder details, critical dimensions and tolerances, sample conditions and target quantity through our contact page, and mention part number C402CR5.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.