(MQQFC046) Quartz Rectangular Sample Cell, 50 mm Path, 130 mL, Open at Both Ends
Description
MQQFC046 is a JGS1 quartz rectangular sample cell for optical setups that need a 50 mm path in a large open chamber. Its Four-Way Light layout gives side access around the rectangular body, while the open ends leave sealing, filling and support to the fixture used in your system. With a 130 mL nominal capacity, this option suits work where chamber size and optical access matter together.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 130 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 50 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 130 mL |
| External Dimensions | 54 × 54 × 52 mm |
| Body Height | 52 mm |
| Base Dimensions | 54 × 54 mm |
| Internal Dimensions | 50 × 50 × 52 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose this cell when you need a long 50 mm transmission path in a rectangular quartz body and want optical access from four sides. It is best suited to custom holders or experimental assemblies where the cell body is integrated into a larger mounting or sealing arrangement instead of supplied as a finished connected flow cell.
What makes this option different
- 50 mm optical path: intended for methods that use a longer transmission length.
- Four-Way Light body: optical access is available from four sides of the rectangular chamber.
- Open at both ends: the end closure and fluid handling can be matched to your own fixture.
- Large chamber volume: 130 mL nominal capacity with 50 × 50 × 52 mm internal dimensions gives a substantial rectangular sample space.
Structure and dimensions

Using this cell
Use this cell as an open sample chamber within a separately designed holder or sealing arrangement. For liquid measurements, define how the sample will be introduced, retained and cleared at each end before routine use.
Keep the mounted orientation consistent between blank and sample. If your method is sensitive to bubbles or residue, check the filling and clearing procedure in the finished assembly rather than assuming the nominal volume alone will define working conditions.
First-use check
- Inspect the optical faces and end edges for damage, residue or handling marks.
- Test the cell in its holder with a blank to confirm alignment and sample retention.
- Before measurement, remove exterior droplets and any visible bubbles from the optical path area.
Fit and optical alignment
Check the body against your fixture using the 54 × 54 × 52 mm external dimensions. The 50 × 50 × 52 mm internal dimensions describe the chamber, not the outside fit of the holder opening.
This is an open-ended sample body, not a complete connected flow cell. Z Height is not listed here, so instrument fit should be judged from your actual beam position and holder geometry rather than from overall body height alone. Support the cell evenly and avoid point loading across the optical faces or end edges.
View the English selection reference.

Solvents and cleaning
This cell is made from JGS1 quartz with powder-fused construction noted for this SKU. If your application involves aggressive chemicals, extended contact time, heat or custom sealing parts, assess the sample and cleaning conditions for the complete assembled setup rather than the cell body alone.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with suitable non-abrasive optical tissue and use a cleaning routine appropriate to the full mounted arrangement.
Included with this option
1 rectangular sample cell, SKU MQQFC046. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, optical path, chamber geometry or end arrangement, send your drawing or labelled sketch together with the critical dimensions, sample conditions and target quantity through the contact page. Include holder details and beam position when fit and alignment are part of the requirement.
Additional information
| Weight | 200 g |
|---|
You must be logged in to post a review.