(MQQFC066) Quartz Screw-Top Cuvette, 16 mm Path, 4.5 mL, Wide Neck
$528.00
JGS1 quartz screw-top cuvette for UV/Vis work with a 16 mm optical path, 4.5 mL nominal capacity and Five-Way Light geometry. Its wide M20 threaded opening uses a top-entry format with electrode access, giving more working room above the sample region than a narrow-neck cell. Sold per piece. Molded 83.
Description
MQQFC066 is a JGS1 quartz screw-top cuvette for UV/Vis measurements that combines a 16 mm optical path with a wide threaded top opening. Its 4.5 mL nominal capacity and top-entry electrode-access format make it useful when you need both a defined optical path and easier access above the sample region. The Five-Way Light layout also gives additional optical access for methods that use more than one viewing direction.
- Path Length
- 16 mm
- Sample Volume (Nominal)
- 4.5 mL
- Opening Configuration
- Threaded Opening with Electrode Access
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 16 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 4.5 mL |
| External Dimensions | 20 × 20 × 36 mm |
| Overall Height with Closure | 42 mm |
| Base Dimensions | 20 × 20 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Port Thread | M20 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Threaded Opening with Electrode Access |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Screw-Top Cuvette |
Choose this option
Choose MQQFC066 when your setup needs a 16 mm path together with a wide-neck threaded opening rather than a narrow filling point. The M20 top thread helps you plan the neck fit and the space needed above the cell, while the 4.5 mL nominal chamber suits methods that use a larger sample volume than microvolume cells. This format is especially useful when filling, positioning or observing the sample from the top matters in daily use.
What makes this option different
- 16 mm optical path for methods built around this longer transmission length.
- 4.5 mL nominal capacity gives a larger chamber for routine filling and sample coverage.
- Wide M20 threaded opening provides more direct top access for filling and for checking clearance above the sample area.
- Threaded opening with electrode access supports top-entry arrangements that need inserted parts at the opening.
- Five-Way Light geometry offers optical access from multiple directions within the cell body.
- Molded 83 fabrication is commonly chosen for methods involving organic solvents or heated conditions, with final suitability depending on the complete assembly and the exact sample and cleaning conditions used.
- Optical-contact / integrated-forming construction identifies the joining style used for this exact source design without turning it into a pressure, sealing or compatibility claim.
Using this cell
Fill the cell from the top and keep the intended 16 mm optical direction aligned with your measurement setup. Before reading, remove bubbles and check that the illuminated region stays covered during the run. The 4.5 mL value is a nominal capacity, not a minimum working volume.
If your method uses an inserted electrode or similar top-entry part, check its diameter, insertion depth and cable routing against your own arrangement. The threaded opening gives a defined neck format, but the evidence reviewed does not establish pressure capability or a tested seal for inserted parts.
First-use check
- Inspect the optical faces, threaded opening and base for chips, residue or transport contamination.
- Place the cell in your holder and confirm that the beam passes through the intended optical faces.
- Run a blank in the final measurement orientation and verify that the sample level covers the illuminated region.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The base is 20 × 20 mm. The bare threaded body is 36 mm high, and the overall height reaches 42 mm when capped. Check holder depth and the vertical clearance needed for the threaded neck, cap handling and any part entering from above.
Z Height is not established for this SKU, so fixed-beam holders should be checked against your actual beam position before ordering. Five-Way Light indicates the supported optical-access category for this cell, but it does not by itself define instrument compatibility or a specific bottom-window arrangement.

Solvents and cleaning
Molded 83 is commonly selected for methods involving organic solvents and for applications that may involve heat, but suitability still depends on the complete assembly and the exact exposure conditions. Choose the sample and cleaning routine for the full wetted and fitted setup used with this cell.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with suitable non-abrasive lab wipes, and review your exact chemical, temperature and contact-time conditions if the method is demanding.
Included with this option
1 Quartz Screw-Top Cuvette and an accompanying closure. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also handle custom JGS1 quartz enquiries for changes such as path length, body size, opening style or other application-specific geometry. If you need a modified version, please send your drawing or holder details and we can review feasibility, quotation and lead time for that separate project.
Send a product-selection enquiry with SKU MQQFC066 and your application details.
Design notes for this configuration: Wide-Neck Quartz Cell: Planning Electrode Access (MQQFC066)
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.











Reviews
There are no reviews yet.