(MQQFC123) Quartz Flow Cell, 10 mm path, 32 µL nominal capacity, 2 mm Optical Opening
$317.00
MQQFC123 is a JGS1 quartz micro flow cell for UV/Vis use with a 10 mm optical path, 32 µL nominal capacity and Two-Way Light configuration. Its 15 mm Z Height and two top M6 fluid connections are the key fit features when beam position and top access both matter. Supplied as 1 piece.
Description
MQQFC123 is a JGS1 quartz micro flow cell for UV/Vis measurements where a low nominal cell volume and a defined beam-center height both matter. It combines a 10 mm optical path, 32 µL nominal capacity, Two-Way Light configuration and a specified 15 mm Z Height in a compact 12.5 × 12.5 × 35 mm body with two top M6 fluid connections.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 32 µL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 15 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 32 µL |
| External Dimensions | 12.5 × 12.5 × 35 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| External Dimensions Scope | Body Only |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Port Thread | M6 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Top Fluid Connections |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC123 when you need a small quartz flow cell with a stated 15 mm bottom-to-beam-center height, not just a compact outside size. The two top M6 connections keep the fluid access above the body, which can suit holders with limited side clearance as long as there is enough space above the cell for the connection hardware.
What makes this option different
- 32 µL nominal capacity in a 10 mm path micro flow-cell format.
- 15 mm Z Height for checking beam-center position against your holder or instrument.
- Two top M6 fluid connections instead of side or end tube access.
- Two-Way Light layout for the main transmission path through the opposed optical faces.
Using this cell
Mount the cell so the body is supported securely and the two top ports remain accessible for your chosen connection hardware. Fill slowly, then inspect the optical region carefully and clear any trapped bubbles before running a blank or taking measurements.
The 32 µL figure is the nominal volume of the cell itself. It should not be treated as a minimum working volume, and the total liquid held by the full setup will also depend on the tubing and connectors outside the cell.
First-use check
- Inspect the optical faces, port openings and body surfaces for chips, residue or transport damage.
- Confirm the 15 mm beam-center height against your holder position before connecting the full circuit.
- After filling, remove bubbles and exterior droplets from the optical area.
- Run the blank under the same installed conditions you will use for measurement.
Fit and optical alignment
View the English selection reference.
The body dimensions are 12.5 × 12.5 × 35 mm, and the stated Z Height is 15 mm from the bottom of the cell to the beam center. Check both values together: the outside body has to seat in the holder, and the beam position has to line up with the measurement path.
The M6 designation identifies the top connection size, but it does not by itself define every fitting detail or instrument match. Leave enough space above the cell for the installed connections and verify holder access before ordering.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer solutions.
Avoid organic samples and organic cleaning solvents for this listed cell. Do not use hydrofluoric acid on quartz, avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 quartz flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz flow-cell projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, connections, fabrication and tolerances. Prototype batches typically involve 2–4 cells, with feasibility, final specification, price and timing confirmed in the project quotation.
Send a product enquiry with SKU MQQFC123, your holder or instrument details, drawing, sample conditions and required quantity.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.