Site Navigation

(MQQFC123) Quartz Flow Cell, 10 mm path, 32 µL nominal capacity, 2 mm Optical Opening

Weight50 g
SKU: MQQFC123

$317.00

In Stock

MQQFC123 is a JGS1 quartz micro flow cell for UV/Vis use with a 10 mm optical path, 32 µL nominal capacity and Two-Way Light configuration. Its 15 mm Z Height and two top M6 fluid connections are the key fit features when beam position and top access both matter. Supplied as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC123 is a JGS1 quartz micro flow cell for UV/Vis measurements where a low nominal cell volume and a defined beam-center height both matter. It combines a 10 mm optical path, 32 µL nominal capacity, Two-Way Light configuration and a specified 15 mm Z Height in a compact 12.5 × 12.5 × 35 mm body with two top M6 fluid connections.

Path Length
10 mm
Sample Volume (Nominal)
32 µL
Opening Configuration
Two Top Fluid Connections

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Z Height15 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)32 µL
External Dimensions12.5 × 12.5 × 35 mm
Cell Body Dimensions12.5 × 12.5 × 35 mm
External Dimensions ScopeBody Only
Body Height35 mm
Base Dimensions12.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Port ThreadM6
Fabrication MethodStandard 80
Opening ConfigurationTwo Top Fluid Connections
Port LayoutTop connection at the left in the referenced original; Top connection at the right in the referenced original
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose MQQFC123 when you need a small quartz flow cell with a stated 15 mm bottom-to-beam-center height, not just a compact outside size. The two top M6 connections keep the fluid access above the body, which can suit holders with limited side clearance as long as there is enough space above the cell for the connection hardware.

What makes this option different

  • 32 µL nominal capacity in a 10 mm path micro flow-cell format.
  • 15 mm Z Height for checking beam-center position against your holder or instrument.
  • Two top M6 fluid connections instead of side or end tube access.
  • Two-Way Light layout for the main transmission path through the opposed optical faces.

Using this cell

Mount the cell so the body is supported securely and the two top ports remain accessible for your chosen connection hardware. Fill slowly, then inspect the optical region carefully and clear any trapped bubbles before running a blank or taking measurements.

The 32 µL figure is the nominal volume of the cell itself. It should not be treated as a minimum working volume, and the total liquid held by the full setup will also depend on the tubing and connectors outside the cell.

First-use check

  1. Inspect the optical faces, port openings and body surfaces for chips, residue or transport damage.
  2. Confirm the 15 mm beam-center height against your holder position before connecting the full circuit.
  3. After filling, remove bubbles and exterior droplets from the optical area.
  4. Run the blank under the same installed conditions you will use for measurement.

Fit and optical alignment

View the English selection reference.

The body dimensions are 12.5 × 12.5 × 35 mm, and the stated Z Height is 15 mm from the bottom of the cell to the beam center. Check both values together: the outside body has to seat in the holder, and the beam position has to line up with the measurement path.

The M6 designation identifies the top connection size, but it does not by itself define every fitting detail or instrument match. Leave enough space above the cell for the installed connections and verify holder access before ordering.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer solutions.

Avoid organic samples and organic cleaning solvents for this listed cell. Do not use hydrofluoric acid on quartz, avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.

Included with this option

1 quartz flow cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz flow-cell projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, connections, fabrication and tolerances. Prototype batches typically involve 2–4 cells, with feasibility, final specification, price and timing confirmed in the project quotation.

Send a product enquiry with SKU MQQFC123, your holder or instrument details, drawing, sample conditions and required quantity.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC123) Quartz Flow Cell, 10 mm path, 32 µL nominal capacity, 2 mm Optical Opening”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare