(MQQMC011) Quartz Micro Flow Cell, 5 mm Path, 45 µL, Stainless Steel Tubes
$317.00
JGS1 quartz micro flow cell with a 5 mm optical path and 45 µL nominal capacity. Its 3 × 3 mm optical window is centred 15 mm above the base; two top stainless steel tubes are 1 mm OD / 0.6 mm ID. A 45 mm body fits within the 55 mm fixed assembly height. Standard 80 adhesive-bonded construction; one cell supplied.
Description
MQQMC011 combines a 5 mm optical path with a 45 µL nominal sample region, a small square optical window and two top stainless steel fluid connections. It is a transmission flow-cell format for methods that require the stated path, beam position and connection geometry together.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 45 µL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 15 mm |
| Optical Window Dimensions | 3 × 3 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 45 µL |
| External Dimensions | 12.5 × 12.5 × 55 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Installed Assembly |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 1 mm |
| Tube Inner Diameter (ID) | 0.6 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Top Fluid Connections |
| Fitting Material | Stainless Steel (grade unspecified) |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Micro Flow Cell |
Choose this option
Choose the 5 mm / 45 µL version for a method specified around a 5 mm measurement path and a small flowing sample region. Check the 3 × 3 mm optical window and 15 mm base-to-beam-centre height separately from sample capacity. A shared outer format does not by itself establish instrument compatibility.
What makes this option different
- 5 mm path / 45 µL nominal capacity: these values identify this option. Nominal capacity is not a minimum working-fill specification.
- 3 × 3 mm optical window: check the illuminated beam size against the measurement opening; it is distinct from the liquid-tube bore.
- 15 mm Z Height: this is the specified base-to-beam-centre distance, rather than the overall cell height.
- Two stainless steel tubes: the fixed top connections are 1 mm OD / 0.6 mm ID. Their material and bore need to suit your sample as well as your tubing arrangement.
Using this cell
Support the body while attaching or removing tubing so that forces do not load the narrow metal connections. Fill and flush the measurement region without bubbles before running a blank. External tubing adds its own volume; use a consistent seating and orientation for blank and sample.
First-use check
- Inspect the optical window, body and two tube ends for damage or residue.
- Verify holder seating and beam access before attaching the complete liquid circuit.
- Flush with a suitable blank, remove bubbles and establish a stable reading before measuring samples.
Fit and optical alignment
The optical body is 12.5 × 12.5 × 45 mm. The fixed assembly, including the top tubes, is 55 mm high; allow additional space for your own tubing and its bend radius. Check holder seating, the 15 mm beam-centre height and the 3 × 3 mm window together.
View the English selection reference.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction for routine room-temperature aqueous samples and buffers. Avoid organic sample solvents and organic cleaning agents on this bonded assembly. Check chemical exposure for the stainless steel tubes and every other wetted connection as well as the quartz body.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe exterior optical faces gently with non-abrasive optical tissue, and keep handling loads off the projecting tubes.
Included with this option
One quartz micro flow cell with the two fixed stainless steel tubes shown. The listed price is per cell; external tubing and adapters are not stated as included.
Availability and ordering
Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects involving optical path, sample region, windows, beam height and connection geometry. Modified designs and prototype batches are quoted separately. Send your drawing, holder details, sample conditions and quantity through the contact page, and include MQQMC011.
Additional information
| Weight | 225 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.