(MQQMC066) Glass Micro Cuvette, 10 mm Path, 1.05 mL, Four-Way Light, Pack of 2
Description
MQQMC066 is a glass micro cuvette for visible spectroscopy and visible-light fluorescence, combining a 10 mm optical path with Four-Way Light access and a 1.05 mL nominal capacity. This version is identified by its 3 mm slit and is supplied as a pack of 2 cells with caps and protective packaging. It suits setups that need a narrower beam region within the sample area while keeping side optical access available.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.05 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Visible Spectroscopy; Visible-Light Fluorescence |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Sales Unit | pack of 2 cells |
| Package Contents | 2 × Glass micro cuvette; Caps and protective packaging |
Choose this option
Choose MQQMC066 when your method uses a standard 10 mm path but the illuminated sample region should stay narrower than a broader micro-cell opening. The 3 mm slit helps you select this narrower option within the series, while the Four-Way Light layout supports visible-light arrangements that use side access around the sample. The two-cell sale unit is also useful for routine bench work where a second cell is helpful for parallel preparation or rotation.
What makes this option different
- 3 mm slit: identifies the narrower sample-region option in this series.
- 10 mm path length: keeps the familiar 1 cm optical path used in many visible-light methods.
- Four-Way Light configuration: provides side optical access for suitable fluorescence or observation layouts.
- Pack of 2 cells: the listed sale unit includes two physical cuvettes with caps.
Using this cell
Fill from the open top and make sure the liquid covers the beam region before measurement. Keep the same orientation for blank and sample so the same optical faces and side-access geometry are used each time.
Work carefully to avoid bubbles and outside droplets in the measurement area. The 1.05 mL figure is a nominal capacity, not a minimum working volume.
First-use check
- Inspect both cells, including the rim and optical faces, after unpacking.
- Rinse with a suitable liquid for your method and run a blank at the working wavelength.
- After filling, confirm beam coverage and recheck for visible bubbles or outside droplets.
Fit and optical alignment
View the English selection reference for this option.
Check the holder opening, seating depth, beam position and beam footprint against your instrument before ordering. The 3 mm slit helps identify this version, but it does not establish Z Height or complete instrument compatibility on its own. If your holder or beam geometry is critical, send the relevant details through the contact page.

Solvents and cleaning
This adhesive-bonded glass cuvette is listed as Standard 80. A chemical-compatibility range is not established for this option, so discuss your sample and cleaning liquid, concentration, temperature and contact time before using organic solvents, aggressive reagents or heated cleaning.
Keep hydrofluoric acid away from glass. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue or another suitable soft material.
Included with this option
2 glass micro cuvettes, caps and protective packaging. The listed price is for one pack of 2 cells. Two cells supplied together are not specified as an optically matched pair.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different geometry or a JGS1 quartz version for another wavelength range, please send your drawing or labelled sketch together with the required path length, sample volume, holder details, beam information and any critical dimensions or tolerances through the contact page.
Additional information
| Weight | 50 g |
|---|