MQQSC036 is a quartz screw-top cuvette with a 5 mm optical path, Four-Way Light configuration and a large screw opening for direct sample access. Accompanying closures are included, and the listed sale unit is a pack of 2.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQSC036 is a quartz screw-top cuvette with a 5 mm optical path, Four-Way Light configuration and a large threaded top opening. This option suits UV/Vis work that uses a shorter path length and also benefits from optical access on four sides of the cell body. The listed sale unit is a pack of 2 with accompanying closures.

Path Length
5 mm
Cell Type
Screw-Top Cuvette
Closure Type
Screw Cap

Selection Specifications

Product KindCuvette
Cell TypeScrew-Top Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length5 mm
Light Transmission ConfigurationFour-Way Light
MaterialQuartz
Closure TypeScrew Cap
Closure IncludedYes
Fabrication MethodMolded 0.01
Sales Unitpack of 2
Package Contents2 × Quartz Screw-Top Cuvette; Accompanying closures

Choose this option

Choose MQQSC036 when you want this 5 mm screw-top configuration supplied as two cells in one order. The large top opening helps with filling and rinsing, while the four-side optical layout is useful when your fixture or measurement geometry needs access beyond a two-face transmission cell.

What makes this option different

  • 5 mm optical path for methods arranged around a shorter transmission length.
  • Four-Way Light configuration for optical access on four sides of the cell body.
  • Large screw opening with included closures for direct top filling and covered handling.
  • Pack of 2 so the listed price covers two cuvettes with accompanying closures.

Using this cell

Fill the cell through the screw opening and fit the closure after loading if your routine calls for a covered sample. Use the same orientation for blank and sample measurements, and make sure the sample covers the illuminated region used by your instrument.

Before measurement, remove visible bubbles and wipe the exterior optical faces clean and dry. Keeping the outer faces free from residue and fingerprints is especially important when you are using multiple optical sides on the same cell body.

First-use check

  1. Inspect the quartz faces and threaded openings for chips, residue or handling marks.
  2. Test holder fit and beam alignment with a suitable blank before running samples.
  3. After filling, check that the closures seat properly and that no bubbles remain in the measurement region.

Fit and optical alignment

View the English selection reference. Also available in the product gallery. Group photographs illustrate options in the series.

Check holder opening, insertion depth and the clearance above the holder for the neck and cap. If your instrument lid or cover sits close to the cuvette position, allow enough room to install and remove the closure comfortably.

Z Height is not established for this SKU, so beam-center compatibility should be checked against your instrument before purchase. Minimum working volume is also not established here, so fill planning should be based on your own instrument geometry and handling method rather than assumed from the listed path length.

English selection reference
Selection reference ↗

Solvents and cleaning

For a method with a defined optical path tolerance, specify that tolerance and its measurement conditions when selecting the Molded 0.01 option. The final requirement is agreed for the order.

This cell is listed as Molded 0.01. It is often selected where tighter path-length control matters, but cleaning and chemical choices should still suit the complete assembled cell, including the closure and any sample-contacting parts.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. For routine cleaning, use non-abrasive lab or optical tissue on the exterior faces and choose a cleaning liquid that is appropriate for the full cell assembly.

Included with this option

2 Quartz Screw-Top Cuvettes with accompanying closures. The listed price is for one pack of 2.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application.

Send a product-selection enquiry with SKU MQQSC036 and your holder, sample and fit requirements.

Additional information

Weight200 g

Reviews

There are no reviews yet.

Be the first to review “(MQQSC036) Quartz Screw-Top Cuvette, 5 mm path, Large Screw Opening, Pack of 2”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare