(MQQSC054) Quartz Screw-Top Cuvette, 10 mm Path, 30 mm Height with Cap, 1.2 mL
$161.00
JGS1 quartz screw-top cuvette for UV/Vis work with a 10 mm optical path, Two-Way Light layout and 1.2 mL nominal capacity. Its 12.5 × 12.5 mm body and 30 mm overall height with cap help when you need a closed top format in a compact footprint. Sold as 1 piece, with screw cap included.
Description
MQQSC054 is a JGS1 quartz Screw-Top Cuvette for UV/Vis measurements with a 10 mm optical path. It combines a 1.2 mL nominal capacity with a compact 12.5 × 12.5 mm body and a threaded top closure, which is useful when you want top access for filling but need to keep the installed cell format short. This option is listed for the 200–2500 nm range.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.2 mL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.2 mL |
| Cell Body Dimensions | 12.5 × 12.5 × 20 mm |
| Overall Height without Closure | 20 mm |
| Body Height | 20 mm |
| Overall Height with Closure | 30 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQSC054 when your method uses a 10 mm path and you want a capped cell rather than an open-top chamber. The screw cap gives direct access from above for filling and emptying, while the 1.2 mL nominal capacity and compact square body make this option easier to place where holder space and top clearance both matter.
What makes this option different
- Screw-cap top access lets you fill and empty the cell from above, then close it for routine handling and measurement.
- 10 mm optical path suits UV/Vis methods built around this common path length.
- Two-Way Light layout supports transmission along the stated optical path without adding side-access claims.
- 1.2 mL nominal capacity keeps the sample region compact in a closed-cell format.
- 12.5 × 12.5 mm body footprint helps with holder fit checks where lateral space is limited.
- 20 mm body height and 30 mm overall height with cap let you assess holder seating and top clearance separately.
- Integrated-forming construction with Molded 83 glossary mapping is a useful selection point for methods that may involve organic solvents, while the limits of the complete capped assembly still need to match your actual chemicals and conditions.
Using this cell
Fill the cell from the top and make sure the sample fully covers the beam path before measurement. After filling, fit the screw cap and keep the same cell orientation for blank and sample readings.
The 1.2 mL value is a nominal capacity, not a minimum working volume. Before reading, check the optical path for bubbles or an incomplete liquid column, and wipe the outside optical faces dry.
First-use check
- Inspect the optical faces, rim and threaded opening before the first fill.
- Place the empty cell in the holder to confirm seating and cap clearance.
- Fill with a suitable blank to check beam coverage, bubbles and exterior droplets.
Fit and optical alignment
The body footprint is 12.5 × 12.5 mm and the uncapped body height is 20 mm. With the cap fitted, the overall height is 30 mm, so top clearance should be checked with the cap in place rather than from the body size alone.
Z Height is not established for this SKU. If your instrument has a fixed beam position, the outer dimensions and 10 mm path length do not by themselves confirm beam alignment.

Solvents and cleaning
This cuvette uses JGS1 quartz with source-listed integrated-forming construction and Molded 83 glossary mapping. That fabrication category is commonly selected for methods that may involve organic solvents, but the chemical limits of this exact capped assembly are not established here and should match your actual sample and cleaning conditions.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive materials intended for laboratory optics.
Included with this option
1 cuvette, with screw cap included. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body format, closure arrangement or another fit-related change, we can review a custom JGS1 quartz version. Send your holder details, beam position, sample conditions and quantity request through this contact page.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.