(MQQST013) Quartz Stoppered Cuvette, 10 mm path, 3.5 mL nominal capacity, Removable Stopper
$257.00
MQQST013 is a JGS1 quartz Stoppered Cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light layout and 3.5 mL nominal capacity. The stoppered opening gives direct top access to the sample chamber, and the listed sale is for 1 piece with an accompanying closure.
Description
MQQST013 is a JGS1 quartz Stoppered Cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 3.5 mL nominal capacity. Its stoppered opening gives direct top access for filling and routine handling, while the 12.5 × 12.5 mm body and 45 mm overall body height help you assess holder space before ordering. The listed sale is for 1 piece with an accompanying closure.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Stoppered Opening
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 38 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Opening Configuration | Stoppered Opening |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Stoppered Cuvette; Accompanying closure |
Choose this option
Choose MQQST013 when you need a stoppered quartz cell with a 10 mm measurement path and side optical access around the sample chamber. This format is useful when your method uses fluorescence geometry supported by a four-side light layout and you want direct top filling rather than a permanently closed flow or plate-style sample region.
What makes this option different
- Stoppered opening gives direct access to the sample chamber from the top for filling and routine handling.
- 10 mm optical path suits methods built around this path length.
- Four-Way Light configuration provides optical access from four sides of the cuvette body for supported fluorescence setups.
- 3.5 mL nominal capacity indicates the chamber size for this cell format and filling style.
- 12.5 × 12.5 mm body with 45 mm overall height gives practical dimensions to check holder clearance.
- 38 mm straight body section is useful when you need to review how much of the body sits within a holder or clamp area.
Using this cell
Fill the cell through the top opening, then place the accompanying closure for your measurement setup. Keep the same optical orientation for blank and sample runs, and make sure the liquid level covers the illuminated region required by your method.
Before measurement, remove visible bubbles from the optical path and wipe the outside faces carefully so residue, droplets and fingerprints do not interfere with the reading. The 3.5 mL figure is a nominal capacity, not a stated minimum working volume.
First-use check
- Inspect the optical faces and sample chamber for chips, dust or transport residue.
- Test holder fit and beam position with a suitable blank before routine measurement.
- Confirm that your fill level covers the measurement region and that the closure can be placed without disturbing seating.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The body cross-section is 12.5 × 12.5 mm, with a 45 mm overall body height and a 38 mm straight body section. Check these dimensions against your holder, lid clearance and surrounding space at the beam position.
Z Height is not specified for this option, so a fixed beam-center instrument should be checked against your current cell, holder or instrument drawing before ordering. Matching the 10 mm path length alone does not establish holder compatibility.

Solvents and cleaning
This cuvette is described by the supplier as using fused-integrated construction. In practice, that is most useful as a handling and cleaning consideration for this exact stoppered quartz cell rather than as a numeric performance grade. For general fabrication background, see Compare fabrication options.
Keep hydrofluoric acid away from quartz, and avoid hot strong alkalis and abrasive cleaning methods. The chemical limits of the full assembly are not established here for this exact SKU, and the stopper material is not specified, so methods involving aggressive chemicals, elevated temperature or solvent contact at the closure area should be checked for full wetted-part suitability before use.
Included with this option
1 Quartz Stoppered Cuvette with accompanying closure. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz requirements related to dimensions, optical path length, sample volume, optical windows and closure style. If you need a different body size or instrument fit, send your drawing or current cell reference through our contact page and we can review the project with you.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.