(C0.12WE1) Quartz Demountable Cuvette, 0.1 mm Path, 30 µL
Original price was: $422.00.$380.00Current price is: $380.00.
JGS1 quartz demountable cuvette for fluorescence spectroscopy with a 0.1 mm optical path and 30 µL nominal capacity. Its sample sits in a shallow rounded-end groove under a removable quartz cover plate, so you can place and inspect the sample before measurement. This selected configuration is supplied with the holder shown.
Description
C0.12WE1 is a JGS1 quartz demountable cuvette for fluorescence spectroscopy with a 0.1 mm optical path and 30 µL nominal capacity. The sample region is a shallow rounded-end groove covered by a removable quartz plate, which gives direct access during loading and lets you check sample placement before closing the cell. This selected option is supplied with the holder shown, so you can order the cell body and its support together for the same setup.
- Path Length
- 0.1 mm
- Sample Volume (Nominal)
- 30 µL
- Closure Type
- Removable Cover Plate
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Demountable Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 0.1 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 30 µL |
| External Dimensions | 45 × 12.5 × 2.6 mm |
| Overall Dimensions with Closure | 45 × 12.5 × 2.6 mm |
| External Dimensions Scope | With Closure |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Removable Cover Plate |
| Closure Material | Quartz |
| Closure Included | Yes |
| Holder Included | Yes |
| Slot Depth | 0.1 mm |
Choose this option
Choose C0.12WE1 when you need a very short path and direct access to the sample region rather than a permanently enclosed chamber. The demountable format is useful when the sample must be placed onto the groove deliberately, checked visually, and then covered before measurement. The included holder also makes this option practical when you want the cell and its support arranged as one kit.
What makes this option different
- The 0.1 mm optical path suits methods that require a very shallow sample layer across the light path.
- The rounded-end groove gives open access to the sample area, which is helpful when placing powders, solids or small liquid amounts directly onto the cell body.
- The removable quartz cover plate lets you inspect the sample position before measurement instead of loading through a fixed top opening.
- The 30 µL nominal capacity keeps this version in the small-volume range without implying a minimum working fill.
- This selected configuration includes the holder shown, so you do not need to source the support separately for this option.
- The listed 45 × 12.5 × 2.6 mm dimensions describe the covered cell body only, not the complete holder-installed assembly.
Using this cell
Place the sample directly into the groove on the cell body, then seat the quartz cover plate on clean contact surfaces before measurement. This open, demountable arrangement is useful when you need to spread, position or inspect the sample manually rather than introduce it into a closed chamber.
The stated 30 µL value is the nominal capacity for this path-length version. It should not be treated as a minimum working volume. If your method depends on how fully the beam area is covered, check that in your actual measurement setup after loading.
First-use check
Before first use, inspect the groove, cover plate and holder contact areas for dust, chips or handling residue. Assemble the cell dry first and make sure the cover plate seats evenly before adding sample.
Fit and optical alignment
The covered cell body measures 45 × 12.5 × 2.6 mm. Those dimensions include the cover plate, but they do not include the full outer envelope of the holder-installed assembly, so leave additional clearance when planning fixtures or instrument space around the holder.
Z Height is not established for this option. If your fluorescence setup depends on a specific beam-center height or support geometry, verify that point against your fixture before ordering.
Solvents and cleaning
Clean the wetted quartz parts with a method suitable for your sample and rinse routine. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning.
Chemical compatibility limits for this exact option are not established here, so aggressive reagents or long contact times should be reviewed for the complete wetted assembly before use. For background on MQ fabrication categories, see MQ Cuvette Fabrication Glossary.
Included with this option
This option includes the demountable quartz cell, its removable quartz cover plate and the holder shown for this configuration.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body or holder arrangement, we can review a custom JGS1 quartz version around your drawing, fixture details and application. Discuss your requirements and quote part number C0.12WE1.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.