(C104CR23) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $293.00.$264.00Current price is: $264.00.
C104CR23 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 700 µL nominal capacity. This stoppered version combines side optical access with a compact sample volume and a 2 mm sample-region width for this selected geometry. Sold per 1 cuvette.
Description
C104CR23 is a quartz micro cuvette for fluorescence spectroscopy that combines a 10 mm optical path, Four-Way Light access and a 700 µL nominal capacity in a stoppered format. Its 2 mm sample-region width and covered opening make it a practical choice when you want a compact cell for handled or volatile samples and need side optical access consistent with this geometry.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104CR23 when your fluorescence setup needs a 10 mm path cell with optical access from four sides and a smaller nominal volume than a larger standard body. The stoppered opening is useful when you want to fill the cell and then keep the sample covered during routine positioning and measurement, while the 2 mm sample-region width helps define the illuminated region you need to align.
What makes this option different
- Four-Way Light configuration for fluorescence setups that use side optical access in this cell geometry.
- 10 mm optical path for methods designed around this standard path length.
- 700 µL nominal capacity in a compact micro cuvette body.
- 2 mm sample-region width to help you assess beam placement within a narrow illuminated region.
- Stopper closure for covered sample handling after filling.
- Fused integrated construction as stated for this option, relevant when reviewing your sample and cleaning routine for a quartz micro cell assembly.
- Quartz body for 200–2500 nm use within the stated wavelength range of this option.
Using this cell
Load the sample carefully, then seat the stopper gently before measurement. Keep the optical faces clean and use a consistent orientation for blank and sample runs so that the beam and observation geometry remain repeatable in your setup.
The 700 µL figure is a nominal capacity, not a minimum working volume. If you intend to run with less than a full fill, check that the liquid still covers the required optical region for your measurement.
First-use check
- Inspect the optical faces, rim and stopper seating area for chips, dust or residue.
- Rinse with a liquid suitable for your method.
- Place the cell in the holder and confirm stable seating and clear optical access in the intended orientation.
- Run a blank at your operating wavelength before routine sample measurements.
Fit and optical alignment
Four-Way Light access supports side optical access, but it does not by itself confirm fit with every fluorescence holder or beam arrangement. The 2 mm sample-region width is especially relevant if your beam footprint or collection geometry is tight, because alignment should be checked against the actual illuminated region rather than assumed from path length alone.
Z Height is not listed for this SKU. If your instrument requires a specified beam-center height, or if top clearance is limited once the stopper is in place, check those points before ordering.
Solvents and cleaning
This option is described as a fused integrated quartz construction. In practical use, that makes the cell a reasonable choice for methods where you want a quartz micro cuvette and will review the sample chemistry and cleaning routine as part of method setup, rather than selecting only by nominal volume or path length.
The exact chemical limits of this selected assembly are not established here, so check your liquid, concentration, temperature and contact time before routine use or cleaning. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For general fabrication background, see Compare fabrication options.
Included with this option
1 cuvette per listed price unit. Stopper included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, beam requirements, sample chemistry and target quantity. Discuss your requirements and quote part number C104CR23.