(C012CF) Quartz Standard Cuvette, 1 mm Path, 350 µL
Description
C012CF is a quartz standard cuvette for methods that use a 1 mm optical path in a straightforward beam-through layout. This version combines an open-top body with a 350 µL nominal capacity, so you can load, inspect and rinse the sample chamber directly from above while working with a compact standard-cell format. A closure is included for this cuvette.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 3.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 3.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C012CF when your method already calls for a 1 mm path and you want a rectangular cuvette body with direct top access rather than a threaded or flow-cell style format. The short path suits higher-absorbance samples or established short-path methods, while the 350 µL nominal capacity keeps the sample region compact without changing to a special-shaped microcell.
What makes this option different
- 1 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 350 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
- Molded 0.01 option: review the required optical-path tolerance and measurement conditions for your order when precision is central to the method.
Using this cell
Fill the cuvette from the top and make sure the liquid level covers the instrument beam during measurement. For repeatable work, keep the same orientation for blank and sample, and clear visible bubbles from the optical region before placing the cell in the holder.
The included closure can be used to cover the cuvette during handling or between preparation steps, but this product is not described as a pressure-rated or leak-tested assembly. If your workflow depends on sealed storage, pressure, or specific long-contact solvent exposure, check the full cell-and-closure combination against those conditions before use.
First-use check
- Inspect the cuvette and closure for shipping damage or contamination.
- Test-fit the empty cuvette in your holder before preparing samples.
- Run a blank using your normal fill practice to confirm beam coverage and orientation.
- Check that your routine sample and rinse conditions are suitable for the complete assembly.
Fit and optical alignment
The listed 12.5 × 3.5 × 45 mm dimensions apply to the body only. Use these body dimensions to check holder seating and the space available above the cuvette, especially if your setup has limited top clearance or if access around the opening matters during filling.
Z Height is not established for this SKU. If your instrument or fixture depends on a specific beam-center height, check holder position and beam alignment before ordering. The 350 µL figure is a nominal body capacity and should not be treated as a minimum working volume.
Solvents and cleaning
This option is listed in the Molded 0.01 fabrication category. In practical selection terms, that category is typically chosen when the cuvette build needs to align with methods that place closer attention on path-length control, but it does not by itself establish a complete solvent list for this exact assembly. If your samples or cleaning routine involve specific organic solvents, aggressive reagents or long soak times, review the full cell-and-closure combination for that use before routine work.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Rinse promptly after use, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Discuss your requirements and mention C012CF.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.