(C205CR1) Quartz Fluorescence Cuvette, 20 mm Path, 12 mL
Original price was: $218.00.$197.00Current price is: $197.00.
C205CR1 is a JGS1 quartz fluorescence cuvette with a 20 mm optical path, Five-Way Light geometry and a 12 mL nominal capacity. Its open-top 20 × 20 × 38 mm chamber gives direct access for filling, rinsing and visual sample checks from above. Sold as 1 cuvette per listed price unit.
Description
C205CR1 is a JGS1 quartz fluorescence cuvette for methods that need a 20 mm optical path together with a larger open sample chamber. This Five-Way Light version combines a 12 mL nominal capacity with direct top access, so it suits work where you want straightforward filling, rinsing and visual inspection in the same cell.
The internal chamber measures 20 × 20 × 38 mm, and the uncapped body measures 26 × 26 × 40 mm. That format gives a broader, deeper sample region than a compact fluorescence cell, while keeping the specified 20 mm path length for your method setup.
- Path Length
- 20 mm
- Sample Volume (Nominal)
- 12 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 20 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 12 mL |
| External Dimensions | 26 × 26 × 40 mm |
| Uncapped Cell Dimensions | 26 × 26 × 40 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 40 mm |
| Internal Dimensions | 20 × 20 × 38 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C205CR1 when your procedure benefits from an open chamber, a larger fill volume and optical access from multiple directions around the sample region. It is a practical choice when you load from above, need room for pipetting or rinsing, and want a 20 mm path in a larger square-body fluorescence cell rather than a narrow or closed format.
What makes this option different
- Open-top access lets you add sample, rinse the chamber and inspect the liquid surface directly from above. This helps when your handling routine is manual and you need clear top clearance around the opening.
- 20 mm optical path gives this cell its defined measurement path without using a long narrow body. It is useful when your method is set up around a 20 mm cell rather than a standard shorter path.
- Five-Way Light geometry provides optical access on multiple faces around the chamber, which can be useful in fluorescence setups that need side access as well as the main transmission path. Instrument fit still depends on your holder and beam geometry.
- 20 × 20 × 38 mm internal chamber creates a relatively large sample region with a 12 mL nominal capacity. This format is easier to fill and rinse than a shallow micro-style chamber, but nominal capacity is not a minimum working volume.
- Powder-fused construction is the supplier’s stated construction term for this exact option. In ordinary use, it identifies this as a fused quartz cell rather than an adhesive-bonded description, so cleaning and sample planning should still be based on your actual chemicals and process conditions for the complete cell.
Using this cell
Fill the chamber from the top and keep the optical region free from bubbles, droplets and residue before measurement. The larger opening is convenient for direct pipetting, decanting and rinse-through cleaning between runs.
Use a consistent cell orientation for blank and sample measurements. This body is an open sample cell, so it should not be treated as a sealed, pressure-rated or evaporation-controlled assembly.
First-use check
- Inspect the chamber opening and optical faces for chips, particles or handling residue.
- Rinse with a cleaning liquid suitable for your method.
- Place the cell in your holder and confirm that the intended optical region lines up correctly.
- Run a blank with your reference liquid before measuring samples.
Fit and optical alignment
The listed 26 × 26 × 40 mm dimensions apply to the uncapped cell body. Check holder width, depth and vertical clearance if your fixture was designed for a smaller fluorescence cell or for a cell with a different top profile.
Five-Way Light describes the optical access arrangement, not automatic instrument compatibility. Z Height is not specified here, so beam-center alignment should be checked before ordering if your holder or instrument requires a defined beam height.
Solvents and cleaning
This JGS1 quartz cuvette is listed for fluorescence spectroscopy over 200–2500 nm. For fabrication background, see MQ Cuvette Fabrication Glossary.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces with non-abrasive optical tissue. Chemical compatibility limits for this exact configuration are not specified here, so check suitability for your sample and cleaning routine before use.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for changes to dimensions, optical path length, sample volume, optical access, Z Height, closures and tolerance requirements. Send a dimensioned drawing or labelled sketch together with holder details, application wavelength, sample conditions and target quantity. Discuss your requirements and mention part number C205CR1.
Additional information
| Weight | 100 g |
|---|