(C304CA2) Quartz Fluorescence Cuvette, 30 mm / 10 mm (dual path) Path, 10.5 mL
Original price was: $156.00.$141.00Current price is: $141.00.
C304CA2 is a JGS1 quartz fluorescence cuvette with a 30 mm primary path, a 10 mm secondary path and four-way optical access in the same cell body. Its 10.5 mL nominal capacity suits methods that use a larger filled sample region rather than a micro-volume format. Price is for 1 cuvette, with a lid included.
Description
C304CA2 is a JGS1 quartz fluorescence cuvette with a 30 mm primary path and a 10 mm secondary path in the same body. Its four-way optical access makes it suitable for fluorescence spectroscopy setups that use more than one optical direction, while the 10.5 mL nominal capacity gives you a larger filled sample region to work with. Price is for 1 cuvette, with a lid included.
- Path Length
- 30 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 10.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 30 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 12.5 × 32.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 32.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C304CA2 when your method uses a longer 30 mm measurement path but also needs side optical access in the same cuvette body. This format is useful when you want direct access through multiple faces for excitation and collection geometry, and when your filling plan suits a 10.5 mL nominal volume rather than a smaller fluorescence cell.
What makes this option different
- 30 mm primary path with 10 mm secondary path gives two stated optical directions in one cuvette body.
- Four-way optical access suits fluorescence spectroscopy arrangements that use beam access from more than one side.
- 10.5 mL nominal capacity provides a larger filled sample region for methods that do not use micro-volume cells.
- JGS1 quartz body supports the stated fluorescence application and wavelength range of 200–2500 nm.
- Fused integrated construction gives an assembled cell body intended to be used as a complete cuvette.
- Single-cuvette sale unit keeps ordering aligned with one priced cell, with a lid included.
Using this cell
Fill the cuvette so the optical region for your selected measurement direction is covered, then place the lid gently before measurement. Keep the same orientation for blank and sample runs, especially when your method depends on a specific excitation and collection direction through the available optical faces.
Check the beam area for bubbles, droplets or dried residue before placing the cuvette in the holder. Because this is a four-way fluorescence format, consistent positioning matters when your setup uses more than one optical direction.
First-use check
Inspect the optical faces for chips, residue or handling marks before first use. Rinse with a liquid suitable for your process, test the empty fit in the holder, and run your usual blank to confirm orientation and optical access in the instrument.
Fit and optical alignment
The outer dimensions apply to the uncapped cell body: 12.5 × 32.5 × 45 mm. Use these uncapped dimensions to check holder seating and compartment clearance, then allow additional space in your own setup for the fitted lid.
Z Height is not established for this option. If your instrument or holder depends on a fixed beam-center height, check that requirement before ordering rather than assuming fit from body size alone.
Solvents and cleaning
This cuvette is made from JGS1 quartz. For general background on quartz cuvette construction choices, see fabrication-method-of-cuvettes.
The chemical limits of the full assembly are not established here, so review your sample and cleaning liquids against your own method before routine use. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Price is for 1 cuvette. A lid is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch, together with your holder or instrument details, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements and quote part number C304CA2.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.