(C032CR) Quartz Standard Cuvette, 3 mm Path, 1.05 mL
Description
C032CR is a JGS1 quartz standard cuvette for methods that use a 3 mm optical path in a compact manually filled format. It combines Two-Way Light transmission with a 1.05 mL nominal capacity and an open-top body supplied with a lid, making it a practical choice when you want a direct-fill quartz cell rather than a flow assembly.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 1.05 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 1.05 mL |
| External Dimensions | 12.5 × 5.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 5.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C032CR when your method is set up around a 3 mm path and you want simple top access for pipetting, rinsing and sample exchange. The 1.05 mL nominal capacity gives you a clear guide to the chamber size, while the included lid helps cover the cell during handling between bench preparation and measurement.
What makes this option different
- 3 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 1.05 mL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Fill the sample chamber from the top opening and make sure the liquid level covers the beam path used by your instrument. Remove visible bubbles before measurement and keep blank and sample oriented consistently if your procedure depends on repeatable placement.
This is a standard filled cell with an open-top body and a separate lid. The available information does not establish a pressure rating or leak-tested sealed use, so it should be used as a manually filled cuvette rather than a pressurised assembly.
First-use check
Before first use, inspect the optical faces for residue or handling marks, rinse the sample chamber with a liquid suitable for your method, and test the dry fit in your holder. On the first filled run, confirm that the beam passes through the intended sample region without the liquid level dropping below it.
Fit and optical alignment
The listed 12.5 × 5.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder fit and body clearance, and leave additional space above the cell if the lid will remain in place during handling.
Z Height is not stated for this SKU. If your instrument has a fixed beam center height or a restrictive holder aperture, check that point before ordering rather than relying on outer body dimensions alone.
Solvents and cleaning
This quartz cuvette is described for use involving acids, alkalis and organic liquids, but no specific concentration, temperature, exposure time or closure compatibility is stated. If your sample or cleaning routine is chemically demanding, check the actual conditions for the full contacting assembly before routine use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For general background on quartz cuvette construction options, see this fabrication guide.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz requirements related to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with holder or instrument information, critical dimensions and tolerances, sample conditions and target quantity. Discuss your requirements and quote part number C032CR.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.