Site Navigation

(MQQMC027) Black-Wall JGS1 Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL, Z Height 15 mm

Weight150 g
SKU: MQQMC027

$191.00

In Stock

MQQMC027 is a JGS1 quartz ultra-micro cuvette for UV/Vis measurements, with a 10 mm optical path, 100 µL nominal capacity and Four-Way Light geometry. Its 15 mm Z Height and 2 × 5 mm window help you match the beam position and optical footprint to a small defined measurement region. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQMC027 is a JGS1 quartz ultra-micro cuvette for UV/Vis measurements that combines a 10 mm optical path with a 100 µL nominal capacity. The Four-Way Light layout, 2 × 5 mm window and 15 mm Z Height make it easier to check whether your beam position and holder geometry suit a compact optical region. Its open top allows direct filling and quick visual inspection before use.

Path Length
10 mm
Sample Volume (Nominal)
100 µL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeUltra-Micro Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationFour-Way Light
Z Height15 mm
Optical Window Dimensions2 × 5 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)100 µL
External Dimensions12.5 × 12.5 × 45 mm
Cell Body Dimensions12.5 × 12.5 × 45 mm
External Dimensions ScopeBody Only
Body Height45 mm
Base Dimensions12.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen Top
Pack Quantity1 Piece

Choose this option

Choose MQQMC027 when you need a 10 mm UV/Vis path in a small-volume cell and want optical access from four sides around a compact measurement area. It is particularly useful when beam height, beam footprint and top-filling clearance all need to be considered together.

What makes this option different

  • 10 mm optical path for UV/Vis methods built around this standard path length.
  • 100 µL nominal capacity in an ultra-micro body for small-volume handling.
  • Four-Way Light configuration for optical access from four sides.
  • 2 × 5 mm window to help assess whether the beam footprint fits the intended optical region.
  • 15 mm Z Height from the base to the optical center for beam-height matching.
  • Open-top body for direct pipette access during filling and rinsing.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill carefully from the top so the sample fully covers the beam path within the defined optical region. With an ultra-micro cell, trapped bubbles or incomplete coverage can interfere with the reading, so check the sample region before you start the run.

Keep the cell orientation consistent between blank and sample measurements. After filling, remove any exterior droplets from the optical faces before placing the cell in the holder.

First-use check

  1. Inspect the rim, body and optical faces before first use.
  2. Check that the holder supports the cell securely at the required beam height.
  3. Run a blank, then confirm that the sample covers the optical region without trapped bubbles.

Fit and optical alignment

The body dimensions are 12.5 × 12.5 × 45 mm, measured on the body only. Check these dimensions together with the top opening clearance if your holder or clamp fits closely around the cell.

The beam center is 15 mm above the base, and the window is marked 2 × 5 mm. If your setup has a defined beam size or limited positioning tolerance, review both values before ordering rather than choosing by body size alone.

View the English selection reference.

English selection reference
Selection reference ↗

Solvents and cleaning

This cuvette uses Standard 80 adhesive-bonded quartz construction. It is best suited to routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded assembly.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a mild cleaning routine.

Included with this option

1 MQQMC027 cuvette. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes involving path length, body dimensions, window layout, Z Height and related geometry. If your holder or optical layout needs a different fit, send your drawing or holder details, critical dimensions, sample conditions and quantity for review.

Send a product-selection enquiry with SKU MQQMC027 and your application details.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQMC027) Black-Wall JGS1 Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL, Z Height 15 mm”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare