(MQQFL021) Quartz Fluorescence Cuvette, 20 mm Path, Four-Way Light

Weight50 g
SKU: MQQFL021

$69.00

In Stock

Quartz fluorescence cuvette for UV/Vis and fluorescence work with a 20 mm optical path, Four-Way Light layout and open-top filling. This option includes a closure and is sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL021 is a quartz fluorescence cuvette for UV/Vis and fluorescence measurements that use a 20 mm optical path and Four-Way Light access. The open-top body allows direct filling, and an included closure can cover the cell during handling or measurement. This option is sold as one piece.

It is a useful choice when your method needs a longer optical path together with side optical access, but you still want straightforward top loading and visual filling control. The supported chemistry note is also important here: this ordinary selected cell is restricted to neutral samples.

Path Length
20 mm
Cell Type
Fluorescence Cuvette
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeUV/Vis Spectroscopy; Fluorescence Spectroscopy
Path Length20 mm
Light Transmission ConfigurationFour-Way Light
MaterialQuartz
Closure TypeFlat Lid
Closure IncludedYes
Opening ConfigurationOpen Top
Pack Quantity1 Piece

Choose this option

Choose MQQFL021 when your setup requires a 20 mm path with optical access from four sides and direct top access to the sample chamber. It suits methods where the path length and window arrangement are already defined, and where neutral-sample handling matches the intended use.

What makes this option different

  • 20 mm optical path for methods set up around this longer path length.
  • Four-Way Light layout for optical access from four sides in suitable UV/Vis and fluorescence arrangements.
  • Open-top filling with an included closure for direct loading and covered handling.
  • Restricted to neutral samples for the ordinary selected cell.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Fill from the top and make sure the liquid level fully covers the illuminated region used by your instrument. For fluorescence work, align the cell so the active windows match the excitation and collection directions of your holder or optical bench.

Keep bubbles, foam and droplets away from the optical faces before measurement. If you use a blank and sample, keep the same orientation and fill condition for both so the optical path and window presentation remain consistent.

First-use check

  1. Inspect the rim, body and optical faces for chips, residue or transit damage.
  2. Test the fit in your holder and confirm that the beam passes through the intended window area.
  3. Rinse with a suitable liquid for your method and remove any bubbles before the first measurement.

Fit and optical alignment

View the English selection reference.

Check the holder opening, available vertical clearance for top filling and the beam position in your instrument before ordering for a fixed holder. The current evidence supports the 20 mm path and Four-Way Light layout, but not a settled nominal capacity or a specified Z Height for this exact option.

The included closure helps cover the opening, but no pressure rating is established here. If your instrument depends on a defined beam-center height or very low fill volume, check the actual holder geometry and working liquid level before purchase.

English selection reference
Selection reference ↗

Solvents and cleaning

This selected ordinary cell is restricted to neutral samples. If your sample, rinse or cleaning procedure involves non-neutral chemistry, please check the exact liquids and conditions with us before ordering a suitable alternative.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive laboratory tissue or another suitable soft cleaning material.

Included with this option

1 quartz cuvette with an included closure. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

If you need a different path length, holder fit, opening style or other geometry, please send your holder details or a labelled drawing. We can review custom quartz requirements case by case, including dimensions, optical path, windows, Z Height and closure details.

Contact us with SKU MQQFL021, your application, sample conditions and any critical fit dimensions.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL021) Quartz Fluorescence Cuvette, 20 mm Path, Four-Way Light”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare