(MQQFL006) Quartz Micro Cuvette, 10 mm path, 1 mm Slit with Screw Closure
$648.00
MQQFL006 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, Five-Way Light layout, 300 µL nominal capacity and screw closure. Its compact body adds capped handling in a small-volume format with multiple optical access faces. Supplied as 1 piece with the accompanying closure.
Description
MQQFL006 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, Five-Way Light layout, 300 µL nominal capacity and screw closure. It suits small-volume work that needs a closed cell and more optical access faces than a simple straight-through format. Supplied as one piece with the accompanying closure, it is also easier to assess for holder clearance because both the body and capped heights are stated.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 300 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 300 µL |
| Cell Body Dimensions | 12.5 × 12.5 × 30 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 41 mm |
| Overall Height without Closure | 41 mm |
| Body Height | 30 mm |
| Overall Height with Closure | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Micro Cuvette; Accompanying closure |
Choose this option
Choose MQQFL006 when your method needs a 10 mm path in a compact screw-closure cell and the optical layout calls for more than two light-access faces. The 300 µL nominal capacity places it between very small micro cells and larger millilitre-scale cells, while the screw closure suits routine filled-cell handling. The listed body and overall heights are also useful when cap clearance matters inside your holder or instrument compartment.
What makes this option different
- Five-Way Light layout: provides optical access on five faces for methods that need more than a simple two-face transmission layout.
- Screw closure included: fill the cell, then close it for routine covered handling.
- 300 µL nominal capacity: a small-volume option without moving to the very lowest micro-volume range.
- Defined height information: 30 mm body height, 41 mm uncapped height and 45 mm overall height with cap help with clearance planning.
- JGS1 quartz body: specified for this listed option.
Using this cell
Fill the cell so the illuminated region is fully covered, then apply the screw closure carefully and keep the same orientation for blank and sample. Because the cell offers multiple optical access faces, keep your chosen measurement direction consistent through the whole method.
Inspect the filled region for bubbles and keep the optical faces free of fingerprints, droplets and dried residue. The nominal capacity does not establish a minimum working volume.
First-use check
- Inspect the optical faces, threaded opening and cap seating surfaces before first use.
- Test holder fit and run a blank in the intended measurement orientation.
- Confirm that the filled sample region is bubble-free and fully covers the beam path.
Fit and optical alignment
The base is 12.5 × 12.5 mm, the main body height is 30 mm, the uncapped height is 41 mm and the overall height with cap is 45 mm. These dimensions help you check holder depth, compartment clearance and access around the cap before ordering.
View the English selection reference.
Z Height is not stated for this option. If your instrument depends on a specific beam-center height, confirm that separately rather than inferring it from the body height or total height.

Solvents and cleaning
Molded 83 is the fabrication type used for this listed cuvette. This fabrication is commonly chosen for methods involving organic solvents and temperature-related applications, but suitability still depends on the complete method and the full wetted assembly, including the closure.
If your work involves aggressive liquids, elevated temperature or long contact time, please send the liquid, concentration, temperature and exposure conditions before ordering. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 Quartz Micro Cuvette with the accompanying closure. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication or tolerance requirements. Prototype batches typically involve 2–4 cells, with feasibility, final specifications, quantity, price and production time confirmed in the project quotation.
Send your enquiry with SKU MQQFL006, your drawing or holder details, sample conditions and target quantity.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.













Reviews
There are no reviews yet.