(MQQFL079) Quartz Fluorescence Cuvette, 8 mm path, 704 µL nominal capacity, Raised-Base Sample Chamber

Weight210 g
SKU: MQQFL079

$257.00

In Stock

MQQFL079 is a JGS1 quartz fluorescence cuvette with an 8 mm optical path, Four-Way Light access and an open-top chamber for direct filling. Its 704 µL nominal capacity and 8 × 8 × 11 mm internal chamber suit UV/Vis and fluorescence work that needs side optical access in a compact 10 × 10 × 22 mm body. The listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL079 is a JGS1 quartz fluorescence cuvette with an 8 mm optical path, Four-Way Light geometry and an open-top chamber for direct sample loading. Its 704 µL nominal capacity and compact 10 × 10 × 22 mm body make it a practical choice when you need small-format quartz construction, access from above and optical access from four side faces. The listed price is for 1 piece.

Path Length
8 mm
Sample Volume (Nominal)
704 µL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeFluorescence Spectroscopy; UV/Vis Spectroscopy
Path Length8 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)704 µL
External Dimensions10 × 10 × 22 mm
Cell Body Dimensions10 × 10 × 22 mm
External Dimensions ScopeBody Only
Body Height22 mm
Internal Dimensions8 × 8 × 11 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Fluorescence Cuvette

Choose this option

Choose MQQFL079 when your method is built around an 8 mm path and you want to fill and inspect the chamber directly from the top. The 8 × 8 × 11 mm internal chamber gives a defined sample region within a short body, which helps when top clearance and holder space are limited. Four-Way Light access also supports side-facing optical layouts used in UV/Vis and fluorescence work with suitable beam geometry.

What makes this option different

  • Open-top access lets you pipette, rinse and visually check the chamber directly from above.
  • Four-Way Light geometry provides optical access from all four side faces for transmission and side-access measurement layouts.
  • 8 mm optical path suits methods that are set up around that specific path length rather than a full 10 mm cell.
  • 8 × 8 × 11 mm internal chamber helps you judge sample region size and filling approach in a compact format.
  • 704 µL nominal capacity offers a small-volume chamber without changing the open-top handling style.
  • Optical-contact / integrated-forming construction means the cuvette is supplied as a fixed body rather than a demountable assembly with separate plates to seat during use.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill the chamber carefully from the top and keep the cuvette orientation consistent between blank and sample measurements. For fluorescence work, keep the same faces aligned to the excitation and collection directions each time so your optical geometry stays consistent from run to run.

The stated 704 µL is a nominal capacity, not a minimum working volume. If you plan to work below a full fill, check in your installed holder that the liquid level fully covers the beam position used by your instrument.

First-use check

  1. Inspect the optical faces and top opening for chips, dust or residue.
  2. Check that the cuvette seats securely and upright in your holder.
  3. Run a blank in the same orientation planned for sample measurements.
  4. After filling, remove bubbles and wipe exterior droplets from the optical faces.

Fit and optical alignment

View the English selection reference.

The stated 10 × 10 × 22 mm dimensions apply to the body only. Use them to check holder clearance, seating depth and the free space you need above the opening for pipette access and cleaning.

Z Height is not stated for this SKU, so instruments or holders with a fixed beam-center height should be checked before ordering. Four-Way Light describes the available optical access, but final fit still depends on your holder geometry and beam position.

English selection reference
Selection reference ↗

Solvents and cleaning

This cuvette is listed under the MQ Molded 83 selection category, and the source describes the construction as optical-contact / integrated-forming. For this SKU, that means you are handling a fixed open-top quartz body rather than assembling separate optical plates before use. Selection for solvent or temperature-related work should still be based on the complete cell and your actual liquid, concentration, temperature and contact time.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with non-abrasive optical tissue, and choose cleaning liquids that suit your actual process conditions.

Included with this option

1 Quartz Fluorescence Cuvette. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures, interfaces, fabrication and tolerances. Send a dimensioned drawing or labelled sketch with your holder details, sample conditions and target quantity through the contact page and reference MQQFL079.

Additional information

Weight210 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL079) Quartz Fluorescence Cuvette, 8 mm path, 704 µL nominal capacity, Raised-Base Sample Chamber”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare