(MQQFC055) Powder-Fused Quartz Rectangular Sample Cell, 12.5 mm Path, 3 mL, Open at Both Ends
Description
MQQFC055 is a JGS1 quartz rectangular sample cell with a 12.5 mm optical path and a 3 mL nominal capacity in an open-through body. It is intended for setups that provide their own holder, sealing method or filling arrangement instead of using a preassembled cuvette. The Four-sided optical layout also gives optical access from multiple sides of the rectangular body.
- Path Length
- 12.5 mm
- Sample Volume (Nominal)
- 3 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 12.5 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3 mL |
| External Dimensions | 17.5 × 17.5 × 20 mm |
| Body Height | 20 mm |
| Base Dimensions | 17.5 × 17.5 mm |
| Internal Dimensions | 12.5 × 12.5 × 20 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
The related options offer different paths, capacities or body sizes in the same open-ended format. Compare material and construction as well as dimensions: MQQFC054 is glass; the other options shown here are quartz.
Choose MQQFC055 when your method is built around a 12.5 mm path and you need an open-ended rectangular cell body that will be mounted externally. The 17.5 × 17.5 × 20 mm outer size helps with fixture clearance, while the 12.5 × 12.5 × 20 mm internal chamber defines the sample space inside the cell.
What makes this option different
- 12.5 mm optical path: suitable for transmission methods built around this path length.
- Four-sided optical layout: optical access is available from multiple sides of the body.
- Open at both ends: sealing, sample retention and filling are handled by your own fixture.
- 3 mL nominal chamber: provided in a 12.5 × 12.5 × 20 mm internal channel.
Structure and dimensions

Using this cell
Nominal capacity is not a minimum working-volume specification. Establish the working fill in your assembled fixture so the illuminated region is fully covered and free of bubbles.
Use this cell where the holder or assembly defines how the sample is introduced, retained and drained. For liquid measurements, set up a filling and bubble-removal procedure in the actual fixture before routine use, since the cell body itself does not include fittings or closures.
Align the beam to the intended 12.5 mm path and keep the same measurement orientation between blank and sample. The stated 3 mL is a nominal cell volume, not a minimum working volume.
First-use check
- Inspect the optical faces and end edges for chips, residue or handling marks.
- Test the fit in the holder before introducing sample.
- Run a blank with your intended mounting and filling arrangement to confirm beam alignment and sample retention.
Fit and optical alignment
Check the holder against the full 17.5 × 17.5 × 20 mm body envelope. The internal 12.5 × 12.5 × 20 mm dimensions describe the sample chamber and should not be used as the holder opening dimensions.
Z Height is not specified for this cell, so beam position needs to be checked in the actual fixture or instrument arrangement. Support the body evenly and avoid point loading across optical faces or end edges.
Solvents and cleaning
This option uses powder-fused quartz construction. Choose the sample and cleaning liquids for the complete wetted assembly, including your end seals and adapters. Compare cuvette fabrication options when specifying a version for a different method.
Clean the optical faces gently with non-abrasive optical tissue and a cleaning liquid suitable for your method. Avoid abrasive cleaners.
Keep hydrofluoric acid away from quartz and avoid hot strong alkalis. If your application involves aggressive chemicals, heated cleaning or extended contact time, check the exact sample and cleaning conditions with us before ordering.
Included with this option
The listed price is for 1 MQQFC055 cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, and tolerances. Send a drawing or labelled sketch together with holder details, sample conditions and the dimensions that are critical to your application.
Prototype batches typically involve 2–4 cells; feasibility, final specifications, quantity, price and production time are confirmed in the project quotation. Send a product-selection enquiry with SKU MQQFC055 and your application details.
Additional information
| Weight | 75 g |
|---|