(MQQFC058) Quartz Rectangular Sample Cell, 0.4 mm Path, 124 µL, Open at Both Ends
Description
MQQFC058 is a JGS1 quartz rectangular sample cell with a 0.4 mm optical path in a slim open-ended body. It combines a long rectangular sample channel with two opposing transmission faces, making it suitable for setups that use a defined short path inside a separate holder or fluid-handling arrangement. The cell body is supplied as the quartz sample section, not as a finished flow assembly with closures or fittings.
- Path Length
- 0.4 mm
- Sample Volume (Nominal)
- 124 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 0.4 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 124 µL |
| External Dimensions | 7 × 2.4 × 62 mm |
| Body Height | 62 mm |
| Base Dimensions | 7 × 2.4 mm |
| Internal Dimensions | 5 × 0.4 × 62 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
The related options offer different paths, capacities or body sizes in the same open-ended format. Compare material and construction as well as dimensions: MQQFC054 is glass; the other options shown here are quartz.
Choose MQQFC058 when your method needs a 0.4 mm optical path and a narrow rectangular channel that can be built into your own fixture. This format is useful when the holder, end sealing and loading method are designed together, and when the outside envelope matters as much as the optical path.
What makes this option different
- 0.4 mm optical path: intended for methods that require a very short stated transmission path.
- Two-face transmission layout: optical access is arranged through two opposing transmission faces.
- Long rectangular channel: the listed 5 × 0.4 × 62 mm internal dimensions create a long, narrow sample region.
- Open-ended body: the cell needs a separate mounting and sealing arrangement rather than direct use as a complete connected assembly.
Structure and dimensions

Using this cell
Nominal capacity is not a minimum working-volume specification. Establish the working fill in your assembled fixture so the illuminated region is fully covered and free of bubbles.
Mount the cell so the beam passes through the 0.4 mm path direction used by your method. Keep that orientation fixed during blank and sample measurements, especially if your fixture allows more than one mounting position.
For liquid handling, set up the full end support, sealing and bubble-removal procedure before routine measurements. The 124 µL nominal capacity describes the cell body itself; the filled and retained volume of the complete setup can change once seals, adapters or tubing are added.
First-use check
- Inspect the transmission faces and end openings before mounting.
- Confirm that the holder supports the body securely without distortion.
- Run a blank in the assembled setup to verify alignment, filling and bubble control.
Fit and optical alignment
Use the 7 × 2.4 × 62 mm external dimensions to check holder clearance and support length. The internal dimensions describe the sample channel only, not the size of the holder opening or clamp feature.
Z Height is not established for this SKU, so beam position should be matched to your actual fixture rather than assumed from the outside height. Support the body evenly and avoid clamping pressure across the optical faces or loading the end edges unevenly.
Solvents and cleaning
Molded 83 is the MQ option generally selected for organic-solvent methods or work involving temperature. For this open-ended body, review the liquid, concentration, temperature and contact time together with the end seals and any other wetted parts of your fixture.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners. If your method involves aggressive chemicals, elevated temperature or long contact times, check suitability for the full assembled setup before use.
Included with this option
1 rectangular sample cell, SKU MQQFC058. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for revised path length, chamber size, external envelope, optical windows, Z Height, closures, interfaces and tolerance requirements. Send your drawing or holder details, the critical dimensions, sample conditions and required quantity for review.
Send a product-selection enquiry with SKU MQQFC058 and your installation details.
Additional information
| Weight | 65 g |
|---|
You must be logged in to post a review.






Reviews