(MQQFC056) Quartz Rectangular Sample Cell, 1 mm Path, 20 µL, Open at Both Ends
Description
MQQFC056 is a JGS1 quartz rectangular sample cell for compact setups that need a short 1 mm optical path in an open-through body. Its 20 µL nominal capacity and Four-sided optical layout make it useful when you want a narrow straight sample channel but plan to provide the holder, sealing method and sample handling separately. This option is supplied as the cell body only.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 20 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 20 µL |
| External Dimensions | 5 × 5 × 20 mm |
| Body Height | 20 mm |
| Base Dimensions | 5 × 5 mm |
| Internal Dimensions | 1 × 1 × 20 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
The related options offer different paths, capacities or body sizes in the same open-ended format. Compare material and construction as well as dimensions: MQQFC054 is glass; the other options shown here are quartz.
Choose MQQFC056 when your method is built around a 1 mm path and a very compact rectangular cell that will be mounted in your own fixture. The 5 × 5 × 20 mm outer body is easy to check for holder clearance, while the open ends leave filling, sealing and retention to your assembly design.
What makes this option different
- 1 mm optical path: suitable for methods built around a short fixed transmission length.
- 20 µL nominal capacity: provided in a straight 1 × 1 × 20 mm internal channel.
- Four-sided optical layout: optical access is available from multiple sides of the body.
- Open at both ends: the cell body does not include a cap, fitting or sealed liquid connection.
Structure and dimensions

Using this cell
Nominal capacity is not a minimum working-volume specification. Establish the working fill in your assembled fixture so the illuminated region is fully covered and free of bubbles.
Set the cell so the beam crosses the intended 1 mm path and keep measurement orientation consistent between blank and sample. Because both ends are open, your fixture must define how the chamber is filled, sealed and cleared of bubbles or droplets before measurement.
The 20 µL value is the nominal chamber volume of the cell body. Working behaviour in use will depend on the mounted position and on the holder or sealing arrangement around the open ends.
First-use check
- Inspect the optical faces and end edges before installation.
- Confirm beam placement and sample position in the actual holder using a blank.
- Check that your support and sealing arrangement fills the channel cleanly and leaves the optical path free of bubbles or droplets.
Fit and optical alignment
Use the 5 × 5 mm base dimensions and 20 mm body height to check holder space and clamping geometry. The internal 1 × 1 × 20 mm dimensions describe the sample channel only and should not be treated as the required holder opening.
Z Height is not specified for this SKU, so final beam-centre fit depends on your holder and beam position. Avoid point loading on the quartz body and do not clamp across optical faces in a way that can stress the cell.
Solvents and cleaning
This quartz option is listed under Molded 83. It is commonly selected for methods that may involve organic solvents or temperature, but suitability still depends on the complete wetted assembly and the actual contact conditions.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with suitable non-abrasive optical tissue.
Included with this option
1 rectangular sample cell, sold as 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, outer envelope, chamber dimensions or a version designed for a particular holder or sealing method, send your drawing or labelled sketch with the critical dimensions and sample conditions. Custom enquiries generally use JGS1 quartz, with feasibility, quantity, price and production time confirmed for the project.
Send a product-selection enquiry with SKU MQQFC056 and your holder or mounting details.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.