Standard 80 adhesive-bonded glass sample cell with a 4 mm optical path, four-sided optical access and 270 µL nominal capacity. The 7 × 7 × 17 mm body is open at both ends for integration into your own holder; intended for routine room-temperature water-based samples and buffers. One cell supplied.
Description
MQQFC054 is a glass rectangular sample cell for compact optical setups that use a separate holder or sealing arrangement. It combines a 4 mm optical path with Four-sided optical access and a 270 µL nominal capacity in an open-through body. This makes it a practical choice when you need a small cell body that will be integrated into your own mounting or fluid-handling design.
- Path Length
- 4 mm
- Sample Volume (Nominal)
- 270 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 4 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 270 µL |
| External Dimensions | 7 × 7 × 17 mm |
| Body Height | 17 mm |
| Base Dimensions | 7 × 7 mm |
| Internal Dimensions | 4 × 4 × 17 mm |
| Material | Glass |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
The related options offer different paths, capacities or body sizes in the same open-ended format. Compare material and construction as well as dimensions: MQQFC054 is glass; the other options shown here are quartz.
Choose MQQFC054 when your setup needs a compact 4 mm path cell with optical access from multiple sides and you will provide the end support separately. The 7 × 7 × 17 mm outer body is easy to check against holder clearance, while the open ends leave retention, sealing and filling to your assembly.
What makes this option different
- 4 mm optical path: suitable for methods and fixtures designed around this shorter transmission length.
- Four-sided optical layout: gives optical access through multiple sides of the rectangular body.
- Open at both ends: no built-in closure or fluid connection is provided on the cell body.
- Compact 270 µL chamber: the internal channel is 4 × 4 × 17 mm within a 7 × 7 × 17 mm outer body.
Structure and dimensions

Using this cell
Nominal capacity is not a minimum working-volume specification. Establish the working fill in your assembled fixture so the illuminated region is fully covered and free of bubbles.
Mount the cell so the beam crosses the intended 4 mm path and keep the same orientation for blank and sample measurements. Because both ends are open, your holder or sealing arrangement needs to control filling, sample retention and bubble removal.
The nominal 270 µL figure describes the cell body itself. If your setup adds seals, adapters or tubing, the liquid retained in the full assembly can be different from the cell’s nominal volume.
First-use check
- Inspect the optical faces and end openings for chips, residue or handling marks.
- Test the fit in your holder before introducing sample.
- Run a blank through your filling and alignment procedure, then check for bubbles, leaks or beam clipping.
Fit and optical alignment
Check holder space against the external 7 × 7 × 17 mm dimensions. The 4 × 4 × 17 mm dimensions describe the internal channel only and should not be used as the holder opening size.
Z Height is not specified for this SKU, so beam-centre fit should be verified in the actual mounted position. Support the body evenly and avoid point loading on transmitting faces or end edges.
Solvents and cleaning
This cell uses Standard 80 adhesive-bonded construction. It is generally selected for routine room-temperature aqueous samples and buffer-based work where the holder and sealing arrangement are designed appropriately.
Avoid organic sample solvents and organic cleaning agents with this adhesive-bonded assembly. For solvent-based or heated methods, compare an appropriate quartz construction and review the complete fixture. Keep hydrofluoric acid away from glass, avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
1 MQQFC054 glass rectangular sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, path length, window layout, interface detail or tolerance target, send your drawing or holder information for review. Custom work is generally coordinated in JGS1 quartz, with feasibility, quantity, price and production time confirmed for the project.
Send a product-selection enquiry with SKU MQQFC054, your holder or sealing concept, sample conditions and required quantity.