(MQQFC053) Quartz Rectangular Sample Cell, 10 mm Path, 4 mL, Open at Both Ends
Description
MQQFC053 is a JGS1 quartz rectangular sample cell for setups that use their own holder, sealing method or sample-handling assembly. It combines a 10 mm optical path with a straight open-through channel and 4 mL nominal capacity, so you can plan the optical path and chamber volume together. This option is useful when you need the cell body itself rather than a complete cuvette with cap or fittings.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 4 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 4 mL |
| External Dimensions | 12.5 × 12.5 × 40 mm |
| Body Height | 40 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Internal Dimensions | 10 × 10 × 40 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
The related options offer different paths, capacities or body sizes in the same open-ended format. Compare material and construction as well as dimensions: MQQFC054 is glass; the other options shown here are quartz.
Choose MQQFC053 when your method is built around a 10 mm transmission path and an open rectangular cell that will be supported externally. The 12.5 × 12.5 × 40 mm outer body gives a clear envelope for holder design, while the open ends leave sealing, filling and drainage to your own assembly.
What makes this option different
- 10 mm optical path: suitable for transmission methods built around this path length.
- Open at both ends: the cell body is intended for use in your own fixture, without an integrated closure or connection.
- 4 mL nominal capacity: provided in a straight 10 × 10 × 40 mm internal channel.
- JGS1 quartz, Two-face transmission: optical access is through two opposite faces of the rectangular body.
Structure and dimensions

Using this cell
Nominal capacity is not a minimum working-volume specification. Establish the working fill in your assembled fixture so the illuminated region is fully covered and free of bubbles.
Install the cell in a holder or clamp that supports the body evenly and defines how the sample will be introduced and retained. For liquid use, decide in advance how the two open ends will be sealed, filled and drained in routine operation.
Keep the beam aligned to the intended transmitting faces and use the same orientation for blank and sample measurements. The stated 4 mL is the nominal volume of the cell body, not a minimum working volume for every assembled setup.
First-use check
- Inspect the optical faces and both end openings for chips, residue or handling marks.
- Check the fit in your holder before adding sample.
- Run a blank in the intended orientation and confirm that filling and bubble removal are controlled in your assembly.
Fit and optical alignment
Use the external 12.5 × 12.5 × 40 mm dimensions to check holder clearance and contact points. The internal 10 × 10 × 40 mm dimensions describe the sample channel and should not be treated as the outer mounting size.
Z Height is not specified for this cell. If your instrument or fixture has a fixed beam height, check beam-centre position in the actual mounted arrangement before ordering or routine use.
Solvents and cleaning
This quartz option is listed under Molded 83. It is commonly chosen for methods that may involve organic solvents or temperature, but actual suitability depends on the complete wetted assembly, including any seals, fittings and contact time.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a cleaning routine suited to the full assembled system.
Included with this option
1 rectangular sample cell, SKU MQQFC053. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to path length, body size, internal channel, openings and fabrication requirements. If your holder uses a specific beam height, sealing layout or end connection design, send a drawing or labelled sketch with the critical dimensions and tolerances.
Send a product-selection enquiry with SKU MQQFC053, your holder or fixture details, sample conditions, required quantity and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.






Reviews