(MQQFC032) Quartz Rectangular Sample Cell, 5/2 mm Dual Path, 450 µL, Open at Both Ends
$275.00
MQQFC032 is a JGS1 quartz rectangular sample cell with 5 mm and 2 mm optical paths in one open-through body. It combines Four-Way Light access with a 45 mm chamber and 450 µL nominal capacity for custom holders or assemblies that manage end support and sample retention separately. Sold as 1 piece.
Description
MQQFC032 is a JGS1 quartz rectangular sample cell with 5 mm and 2 mm path directions, Four-Way Light access and an open-at-both-ends chamber. It suits custom optical assemblies that need this path pair in a longer rectangular body, while the surrounding holder or fixture provides the end support, sealing or sample-handling arrangement.
The outside dimensions are 7.5 × 4.5 × 45 mm, and the nominal volume is 450 µL. This gives you the longer format in the 5/2 mm geometry when chamber length and body envelope both matter in fixture planning.
- Path Length
- 5 mm / 2 mm (dual path)
- Sample Volume (Nominal)
- 450 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 5 mm / 2 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 450 µL |
| External Dimensions | 7.5 × 4.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 7.5 × 4.5 mm |
| Internal Dimensions | 5 × 2 × 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC032 when you need the 5 mm and 2 mm path pair together with a 45 mm chamber length in an open-through quartz body. It is a practical option for dedicated holders and rig-built optical systems where the cell body must fit a specific external space and the assembly itself determines how the sample is introduced and retained.
What makes this option different
- Dual 5/2 mm optical paths: one body provides two defined beam directions for method-specific orientation.
- 45 mm chamber length: a longer body format for setups that need more chamber length within the same path combination.
- Open at both ends: intended for custom end support, closure or sample-handling arrangements.
- 450 µL nominal capacity: a longer-volume format in this 5/2 mm rectangular design.
Structure and dimensions

Using this cell
Install the cell so the beam crosses the intended 5 mm or 2 mm direction, and keep that orientation constant during the measurement sequence. Because both ends are open, sample loading, retention and venting are defined by the holder or sealing arrangement used around the cell body.
For liquid measurements, establish the fill, drain and bubble-removal procedure in the assembled setup before use. The listed 450 µL is the nominal chamber volume of the cell body and does not represent the total volume of an attached flow path or a minimum working fill.
First-use check
- Inspect the optical faces, end edges and chamber openings before mounting.
- Confirm the holder supports the body evenly and without twisting.
- Check the selected 5 mm or 2 mm beam direction with a blank in the intended orientation.
- Verify that your end-sealing or retention method controls bubbles and exterior wetting before recording data.
Fit and optical alignment
Use the external dimensions of 7.5 × 4.5 × 45 mm when checking fixture fit. The internal 5 × 2 × 45 mm dimensions describe the chamber space only and should not be used as the holder-opening size.
Z Height is not specified for this SKU. If your instrument requires a defined beam-center position, confirm alignment from the actual holder design rather than assuming standard cuvette geometry. Support the body without concentrated clamping across the optical faces.

Solvents and cleaning
This model is listed under Molded 83, a fabrication category often chosen for organic-solvent methods and applications that may involve heat. Suitability should be assessed for the complete assembly, including any separate seals, fittings or holder materials used with the open-ended body.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive optical tissue or another suitable low-abrasion method.
Included with this option
1 rectangular sample cell, SKU MQQFC032. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also coordinate custom JGS1 quartz projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closure details or fabrication requirements. If you need a modified version, send your drawing or holder details, critical dimensions, sample conditions and target quantity through this contact page.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.