(MQQFC031) Quartz Rectangular Sample Cell, 5/2 mm Dual Path, 270 µL, Open at Both Ends
$245.00
MQQFC031 is a JGS1 quartz rectangular sample cell with 5 mm and 2 mm optical paths in one open-through body. The Four-Way Light layout, 270 µL nominal capacity and compact 7.5 × 4.5 × 27 mm exterior suit custom fixtures that need a wider secondary path without an integrated cuvette assembly. Sold as 1 piece.
Description
MQQFC031 combines 5 mm and 2 mm optical paths in a JGS1 quartz rectangular sample cell with Four-Way Light access. Its open-at-both-ends construction makes it useful when the cell body will be built into your own holder, seal or experimental assembly rather than used as a complete self-contained cuvette.
The body remains compact at 7.5 × 4.5 × 27 mm, while the nominal volume is 270 µL. This format is useful when you need the 5/2 mm path pair and a wider internal chamber than the 5/1 mm versions, but still want a short body height.
- Path Length
- 5 mm / 2 mm (dual path)
- Sample Volume (Nominal)
- 270 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 5 mm / 2 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 270 µL |
| External Dimensions | 7.5 × 4.5 × 27 mm |
| Body Height | 27 mm |
| Base Dimensions | 7.5 × 4.5 mm |
| Internal Dimensions | 5 × 2 × 27 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC031 when your method needs the 5 mm and 2 mm path pair in one compact rectangular body and optical access from four sides matters to the setup. It is especially suitable for custom-mounted work where the holder defines how the sample chamber is supported, sealed or connected at each end.
What makes this option different
- Dual 5/2 mm optical paths: one cell body supports two stated beam directions, including a wider secondary path than the 5/1 mm format.
- Four-Way Light geometry: optical access is available from four sides of the rectangular body.
- Open at both ends: suited to assemblies that use separate end support, sample retention or sealing parts.
- Compact short body: the 7.5 × 4.5 × 27 mm envelope helps when fixture space is limited.
Structure and dimensions

Using this cell
Orient the cell so the beam passes through the intended 5 mm or 2 mm direction, and keep that orientation consistent throughout the measurement sequence. Because the chamber is open at both ends, your holder or sealing method determines how the sample is retained, vented and kept free of bubbles in the beam area.
For liquid use, establish the filling and end-closing procedure before measurement rather than treating the body as a ready-to-use cuvette. The stated 270 µL is the nominal chamber volume of the cell body and does not define a minimum working volume for the completed setup.
First-use check
- Inspect the optical faces, end edges and chamber openings before installation.
- Confirm the cell sits squarely in the holder without twisting.
- Verify the selected 5 mm or 2 mm beam direction with a blank.
- Check your end support or retention method for bubbles or exterior wetting in the beam area.
Fit and optical alignment
Use the external size of 7.5 × 4.5 × 27 mm when checking holder clearance and contact points. The internal 5 × 2 × 27 mm dimensions describe the chamber itself, not the fixture opening needed around the outside of the cell.
Z Height is not specified for this SKU, so beam-center matching should be checked against the actual mount and optical path in your instrument. Support the cell body evenly and avoid clamping pressure across the transmitting faces.

Solvents and cleaning
This cell is listed under Molded 83, a fabrication category often selected for organic-solvent methods and applications that may involve heat. Suitability should be judged for the full arrangement, including any separate seals, fittings or holder materials used with this open-ended body.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive optical tissue or another suitable low-abrasion method.
Included with this option
1 rectangular sample cell, SKU MQQFC031. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also coordinate custom JGS1 quartz projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closure details or fabrication requirements. If you need a modified version, send your drawing or holder details, critical dimensions, sample conditions and target quantity through this contact page.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.