(MQQFC029) Quartz Rectangular Sample Cell, 5/1 mm Dual Path, 135 µL, Open at Both Ends
$269.00
MQQFC029 is a JGS1 quartz rectangular sample cell with 5 mm and 1 mm optical paths in one open-through body. The Four-Way Light layout and 135 µL nominal capacity suit compact custom fixtures that need optical access from multiple sides rather than an integrated cuvette assembly. Sold as 1 piece.
Description
MQQFC029 is a compact JGS1 quartz rectangular sample cell for optical setups that need both 5 mm and 1 mm path directions in the same body. Its Four-Way Light layout and open-at-both-ends chamber make it useful when the cell will be built into your own holder, seal or flow arrangement rather than used as a complete assembled cuvette.
The body size stays small at 7.5 × 3.5 × 27 mm, while the nominal volume is 135 µL. That combination helps when fixture space is limited and you want the sample chamber dimensions and outside envelope to stay tightly defined.
- Path Length
- 5 mm / 1 mm (dual path)
- Sample Volume (Nominal)
- 135 µL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 5 mm / 1 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 135 µL |
| External Dimensions | 7.5 × 3.5 × 27 mm |
| Body Height | 27 mm |
| Base Dimensions | 7.5 × 3.5 mm |
| Internal Dimensions | 5 × 1 × 27 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC029 when your setup needs a small rectangular quartz cell body with two stated optical directions, 5 mm and 1 mm, and access from four sides. It is a practical choice for custom optical mounts where the surrounding hardware will determine how the ends are supported, closed or connected during use.
What makes this option different
- Dual 5/1 mm optical paths: one cell body supports two defined beam directions, so you can choose the orientation that matches your method.
- Open at both ends: suitable for assemblies that use separate end support, sealing or sample-handling parts.
- Four-Way Light geometry: optical access is available from four sides of the rectangular body.
- Compact outer size: the 7.5 × 3.5 × 27 mm envelope helps when holder clearance is limited.
Structure and dimensions

Using this cell
Install the cell so the beam crosses the intended 5 mm or 1 mm direction, and keep that orientation consistent between blank and sample measurements. Because both ends are open, the way you fill, retain and vent the sample depends on the fixture or sealing method used around the cell body.
This is a cell body, not a ready-to-connect flow cell with built-in fittings or caps. The stated 135 µL is the nominal chamber volume of the cell itself and should not be treated as the minimum working volume of your assembled setup.
First-use check
- Inspect the optical faces and end edges for chips, residue or handling marks.
- Test the fit in the holder before introducing sample.
- Verify the chosen 5 mm or 1 mm orientation with a blank.
- Check that your end support or sealing method keeps the beam area free of visible bubbles.
Fit and optical alignment
Use the external dimensions, 7.5 × 3.5 × 27 mm, to check holder clearance and support points. The internal 5 × 1 × 27 mm dimensions describe the sample chamber, not the fixture opening required around the outside of the cell.
Z Height is not specified for this SKU, so beam-center alignment should be verified in the actual holder rather than assumed from the body dimensions alone. Support the quartz evenly and avoid concentrated clamping on the optical faces or end edges.

Solvents and cleaning
This cell is listed under Molded 83, a fabrication category often selected for organic-solvent methods and applications that may involve heat. Suitability still depends on the complete assembly, including any seals, fittings or support parts used with this open-ended body.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive optical tissue or another suitable low-abrasion method.
Included with this option
1 rectangular sample cell, SKU MQQFC029. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also coordinate custom JGS1 quartz projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closure details or fabrication requirements. If you need a modified version, send your drawing or holder details, critical dimensions, sample conditions and target quantity through this contact page.
Additional information
| Weight | 50 g |
|---|