Site Navigation

(MQQFC118) Custom Quartz Flow Cell, Drawing-Based Configuration

Weight75 g
SKU: MQQFC118

$6.00

In Stock

MQQFC118 is a custom quartz flow cell built around a drawing-based specification rather than a fixed standard body. This option keeps the 0.6 mm optical path, Two-Way Light layout, two-port flow-cell format and Molded 83 fabrication, while the remaining geometry is defined for your installation. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
SKU: MQQFC118 Categories: , , Tags: ,
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC118 is a custom quartz flow cell for UV/Vis work where the physical layout needs to be set around the instrument, holder and liquid path instead of chosen from a fixed catalogue body. This option keeps a 0.6 mm optical path in a Two-Way Light, two-port flow-cell format, and it is suited to projects where connection layout, mounting faces or overall envelope need to be agreed before production.

It is a practical choice for replacement parts, tight installation spaces and development work based on a drawing, labelled sketch or existing sample. The listed sale unit is one custom flow cell.

Path Length
0.6 mm
Cell Type
Flow Cell
Light Transmission Configuration
Two-Way Light

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length0.6 mm
Light Transmission ConfigurationTwo-Way Light
MaterialQuartz
Port Count2
Pack Quantity1 Piece
Fabrication MethodMolded 83
Package Contents1 × Custom Quartz Flow Cell

Choose this option

Choose MQQFC118 when the optical path is already defined at 0.6 mm but the surrounding geometry is project-specific. That can mean matching an existing holder, keeping ports in a particular direction, fitting a restricted instrument space or rebuilding a flow assembly around an older part that is easier to copy from a drawing than from a generic size label.

What makes this option different

  • Drawing-based configuration lets the body shape and installation details be set for the project instead of taken from a fixed stock geometry.
  • 0.6 mm optical path keeps the selected short-path flow-cell format while the rest of the design is discussed.
  • Two-Way Light, two-port layout suits straight-through optical use in a custom flow assembly.
  • Molded 83 fabrication is the selected construction direction for this custom flow-cell option.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Use the agreed drawing as the working reference for mounting, fluid connections and optical direction. When sending your request, mark the dimensions that control fit in the holder, show how the tubing approaches the cell, and identify any surfaces that locate the part during installation.

If you are replacing an existing flow cell, a labelled photo, marked sketch or dimensioned drawing is usually the fastest way to describe the part. For liquid handling, include the sample liquid, concentration, temperature, contact time and any flow or pressure conditions that matter to the assembly, because those conditions affect how the custom design should be reviewed.

First-use check

  1. Compare the delivered cell with the agreed drawing before installation.
  2. Check mounting fit, port access and optical direction with a suitable blank before running sample.
  3. After assembly, fill slowly and inspect the optical region for bubbles or misalignment in the installed position.

Fit and optical alignment

View the English selection reference.

The outside dimensions, body height, nominal capacity and beam-center height are defined for your project in the agreed drawing. If your holder requires a specific beam position, insertion depth, tube size, thread or mounting face, include those details in the enquiry so the drawing can be checked against your setup before production.

English selection reference
Selection reference ↗

Solvents and cleaning

This option uses Molded 83 as the selected fabrication category. If your project involves organic solvents or temperature-related operating conditions, include those details with the drawing so the complete design can be reviewed in context.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. The final cleaning routine should follow the agreed cell design and the liquids used in the complete assembly.

Included with this option

1 custom quartz flow cell, made to the agreed project specification and quotation.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

Send your drawing or labelled sketch, instrument or holder details, required path length, connection layout, critical dimensions and tolerances, sample conditions, quantity and target date through Discuss your requirements. Prototype batches typically involve 2–4 cells, with final feasibility, specification, price and production time confirmed in the quotation.

Additional information

Weight75 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC118) Custom Quartz Flow Cell, Drawing-Based Configuration”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare