(MQQFC001) Online Water-Analysis Flow Cell, Metal End Connections
$480.00
This online water-analysis flow cell has a quartz body, opposite-end metal connections and a straight Two-Way Light optical layout for UV/Vis work. It is supplied as 1 complete cell and suits installations built around this inline connection style rather than a standard top-fill cuvette format.
Description
MQQFC001 is an online water-analysis flow cell with a quartz body and metal connections at opposite ends of the cell. It is intended for UV/Vis use in an inline liquid path, where the cell is part of a connected system rather than a manually filled cuvette position.
This option uses Two-Way Light transmission and a straightforward end-to-end connection layout. It is supplied as one complete cell, which is useful when you are replacing a single installed flow-cell position or building one matching measurement channel around this connection style.
- Cell Type
- Flow Cell
- Light Transmission Configuration
- Two-Way Light
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Pack Quantity | 1 Piece |
| Fabrication Method | Molded 83 |
| Port Layout | End/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original |
| Package Contents | 1 × Online Water-Analysis Flow Cell |
Choose this option
Choose this option when your setup is based on an inline flow cell with opposite-end connections and you need this general body style for a UV/Vis water-analysis installation. The main point to check is the physical layout of the cell and its end connections, because tubing direction, holder access and beam access all depend on that geometry.
What makes this option different
- Inline flow-cell format for liquid circulation through the optical section.
- Two-Way Light layout for straight-through optical access in UV/Vis setups.
- Metal connections at opposite ends to suit installations built around end-connected tubing.
- Sold as 1 complete cell for one installation or replacement position.
Structure and dimensions

Using this cell
Install the cell so the body is supported independently and the metal end connections are not carrying the weight of the tubing. Plan the fluid route before use, then fill the circuit slowly and inspect the illuminated region for trapped bubbles before taking a blank or background.
Keep the exterior optical faces clean and dry during operation. If your system includes pumps, valves or other fittings, set operating conditions for the complete assembled liquid path rather than assuming limits from the cell body alone.
No pressure limit is specified for this SKU, and the path length and nominal volume are not established in the reviewed evidence. Selection should therefore be based on the installed geometry and your matched application requirement, not on an assumed standard flow-cell size.
First-use check
- Inspect the optical faces and connection areas for shipping damage or residue before installation.
- Mount the cell with proper support, then verify beam alignment with a suitable blank.
- Fill slowly, remove visible bubbles from the optical region and repeat the blank under the same circuit conditions.
Fit and optical alignment
View the English selection reference. This helps you compare the body style and connection arrangement with your current installation.
Before ordering, check holder clearance around the cell body, beam access through the optical faces and free space for tubing beyond both ends. Z Height is not established for this SKU, so instrument fit should be checked against your actual holder or optical bench arrangement rather than assumed from the general shape.
Because no verified dimensional drawing is available here, this listing should be matched to a known replacement layout or to your own installation reference.

Solvents and cleaning
This model uses Molded 83 construction with a quartz body in JGS1 grade. This construction is commonly chosen where a quartz flow cell is needed for methods that may go beyond routine water-based handling, but chemical suitability still needs to be judged from the complete wetted assembly.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and wipe the exterior optical faces gently with non-abrasive optical tissue. When reviewing cleaning or sample liquids, consider the cell body, metal connections, tubing and any seals in the full system together.
Included with this option
1 Online Water-Analysis Flow Cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If this layout is close to your requirement but not the right fit, we can review a separate custom JGS1 quartz project based on your holder layout, connection arrangement or other installation needs. Please send your drawing or holder details, sample conditions and quantity through our contact page, and mention SKU MQQFC001.
Design notes for this configuration: Quartz Flow Cell for an Online Nitrogen Analyser: Checking Replacement Interfaces