Site Navigation

(MQQFC121) JGS1 Quartz Flow Cell, 50 mm Path, Top and Side Tubes

Weight80 g
SKU: MQQFC121

$359.00

In Stock

A JGS1 quartz Flow Cell for UV/Vis work with a 50 mm optical path, Two-Way Light geometry and 16 mL nominal capacity. Top and side tube connections use different sizes, which helps you plan tubing and holder clearance together. Price is for one cell.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

For UV/Vis flow setups that call for a 50 mm optical path, MQQFC121 pairs a JGS1 quartz cell with top and side tube connections. Its 16 mL nominal capacity and individually specified tube sizes help you plan the cell, tubing and holder as one assembly.

Path Length
50 mm
Sample Volume (Nominal)
16 mL
Opening Configuration
Two Unequal Tube Connections

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length50 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)16 mL
External Dimensions52.5 × 12.5 × 45 mm
Body Height45 mm
Base Dimensions52.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Opening ConfigurationTwo Unequal Tube Connections
Port LayoutUpright tube on the top face as drawn; Horizontal tube on the near side face as drawn
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose MQQFC121 when your method needs a long 50 mm flow path and your layout can accommodate one upright top tube and one side tube. This option is especially useful when connection size matters as much as optical path, because the two tubes are not the same size and need to be matched separately in your fluid line design.

What makes this option different

  • 50 mm optical path for UV/Vis methods built around a longer transmission path.
  • Top and side tube layout for installations that need access from two different directions.
  • Unequal connection sizes: top tube OD 6 / ID 4 mm; side tube OD 5 / ID 3 mm.
  • 16 mL nominal capacity in a 52.5 × 12.5 × 45 mm body format.

Structure and dimensions

Top and side tube dimensions for planning your connections. Schematic, not to scale.
Top and side tube dimensions for planning your connections. Schematic, not to scale.Open image ↗
Upright view of the MQQFC121 Flow Cell. Price is per cell.
Upright view of the MQQFC121 Flow Cell. Price is per cell.Open image ↗

Using this cell

Support the body of the cell during installation and connect the tubing without twisting or pushing sideways on the tubes. Fill and flush the cell in a way that clears bubbles from the optical region, and keep the same orientation for blank and sample measurements.

The two connection positions describe the physical geometry only. They do not assign inlet and outlet roles, so you can define flow direction in your own setup if the tubing and holder arrangement allow it.

First-use check

  1. Inspect the optical faces and both tube connections before installation.
  2. Check holder support and tubing clearance without forcing the tubes.
  3. Establish a bubble-free blank before measuring samples.

Fit and optical alignment

The bare cell body measures 52.5 × 12.5 × 45 mm. Allow additional clearance for the projecting tubes, tubing bends and any support hardware, because the overall assembled envelope is larger than the body alone.

Z Height is not listed for this option, so instrument fit should not be assumed from outer dimensions alone. If your holder or optical bench depends on a defined beam-center height, check that requirement before ordering.

View the English selection reference. View the dimensions before selecting your holder.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses JGS1 quartz. Compare fabrication options if your method involves organic solvents, heating or prolonged contact, and include the chemical, concentration, temperature and contact time in your enquiry.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis, abrasive cleaners and force on the projecting tubes. Use non-abrasive optical tissue on the external optical faces.

Included with this option

One MQQFC121 quartz Flow Cell. The price covers one cell; please specify any additional tubing, connectors or supports in your enquiry.

Availability and ordering

Order the listed specification directly, or contact us first to check availability and dispatch timing. A temporarily unavailable option may need additional preparation or production time. If you have a required delivery date, please check with us before ordering; preparation and shipping transit are separate.

Discuss a custom version

For a modified version, send a labelled drawing showing the path length, body dimensions, tube positions and tube OD/ID. Include your holder details, sample conditions, fluid route and any pressure, flow, tolerance or documentation requirements.

Discuss your application and quote MQQFC121, quantity and delivery destination.

Additional information

Weight80 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC121) JGS1 Quartz Flow Cell, 50 mm Path, Top and Side Tubes”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare