(MQQMC042) Quartz Micro Cuvette, 10 mm path, 100 µL nominal capacity, 2 mm Slit, Block-Shaped Cell
$64.00
MQQMC042 combines a 10 mm optical path and 100 µL nominal capacity in a shallow 12.5 × 12.5 × 8 mm body. Its black exterior and 2 mm sample slit distinguish this open-top JGS1 quartz micro cuvette from a conventional tall cell. Standard 80 construction for room-temperature aqueous work; sold as one cell.
Description
MQQMC042 is a compact quartz micro cuvette for UV/Vis spectroscopy when you need a 10 mm path length in a small-volume format. This version combines a 100 µL nominal capacity with a 2 mm sample slit and an open top in a shallow body, for fixtures designed to support and align this low body.
Made from JGS1 quartz, it uses a Two-Way Light layout for straightforward transmission measurements. The body dimensions are 12.5 × 12.5 × 8 mm, so it is useful for checking fit in low-profile fixtures, while keeping in mind that the 8 mm figure is body height rather than beam-center height.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 100 µL |
| External Dimensions | 12.5 × 12.5 × 8 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 8 mm |
| External Dimensions Scope | Body Only |
| Body Height | 8 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Detection Channel Width | 2 mm |
| Package Contents | 1 × Quartz Micro Cuvette |
Choose this option
Choose MQQMC042 when your method is set up for a 10 mm UV/Vis path but you want a smaller nominal volume than a larger standard cell body. The open top provides filling access. Choose it for a fixture that supports the shallow body and places the sample region at the beam, rather than for low height alone.
What makes this option different
- 10 mm optical path in a compact micro cuvette format for UV/Vis measurements.
- 100 µL nominal capacity for methods using a small sample charge.
- 2 mm sample slit identifies the narrow measurement region; actual clear beam access still needs to suit your instrument.
- 12.5 × 12.5 × 8 mm body for shallow holder layouts; the 8 mm value is body height, not Z Height.
Structure and dimensions

Using this cell
Fill the cell from the open top and make sure the illuminated region is fully covered before measurement. In a small-volume cell, bubbles, droplets and inconsistent fill level can affect results quickly, so it helps to load slowly and check the sample region before each run.
Use the same orientation for blank and sample measurements. The 100 µL figure is the nominal capacity of the cell, not a minimum working volume, so the practical fill level depends on your beam position and beam size in the instrument.
First-use check
- Inspect the optical faces and sample region for chips, residue or fingerprints.
- Place the empty cell in the holder to confirm stable seating and beam access.
- Run a blank in the same orientation and fill style planned for the sample.
Fit and optical alignment
View the English selection reference.
The listed outer dimensions apply to the bare body only: 12.5 × 12.5 mm base and 8 mm body height. Use these figures to check holder seating and nearby clearance. The 2 mm slit is not a guaranteed clear optical aperture, and the 8 mm height is not Z Height. A holder designed for a 45 mm tall cuvette cannot be assumed to align this shallow cell. Z Height is not specified for this SKU, so if your instrument requires a defined beam-center position, that point should be checked before ordering.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction commonly chosen for room-temperature water-based samples and buffers. Avoid organic sample solvents and organic cleaning agents with this construction. If your method uses organic solvents, a suitable Sintered or Molded alternative may be a better fit.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive materials.
Included with this option
1 Quartz Micro Cuvette. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows, Z Height and fabrication details. Send a custom enquiry with SKU MQQMC042, your holder details or drawing, critical dimensions and your application conditions.
For a modified JGS1 quartz version, send a labelled drawing, holder and beam details, sample and cleaning conditions, and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation.
Additional information
| Weight | 60 g |
|---|