JGS1 quartz screw-top cuvette for UV/Vis work with a 3 mm optical path, Four-Way Light geometry and 1050 µL nominal capacity. The M10 screw-cap neck gives direct top access in a compact short-path cell. The listed price is for 1 piece with an accompanying closure. Molded 83.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQSC007 is a JGS1 quartz screw-top cuvette for UV/Vis spectroscopy with a 3 mm optical path, Four-Way Light configuration and 1050 µL nominal capacity. Its M10 screw-cap neck gives direct filling access together with a covered sample chamber, making it a practical option when you want a short-path upright cell rather than an open-top format. This sales option is supplied as 1 piece with an accompanying closure.

Path Length
3 mm
Sample Volume (Nominal)
1.05 mL
Closure Type
Screw Cap

Selection Specifications

Product KindCuvette
Cell TypeScrew-Top Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length3 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.05 mL
Cell Body Dimensions12.5 × 5.5 × 38 mm
Overall Height without Closure54 mm
Body Height38 mm
Overall Height with Closure58 mm
Base Dimensions12.5 × 5.5 mm
MaterialQuartz
Material GradeJGS1
Closure TypeScrew Cap
Closure IncludedYes
Fabrication MethodMolded 83
Closure ThreadM10
Pack Quantity1 Piece
Package Contents1 × Quartz Screw-Top Cuvette; Accompanying closure

Choose this option

Choose MQQSC007 when your method is set up for a 3 mm path and you want a screw-top sample chamber with optical access on four sides. The 1050 µL nominal capacity gives more sample space than very small-volume short-path cells, while the M10 neck keeps filling and closing straightforward. It is a useful format for routine UV/Vis work where path length, top access and holder fit all need to be considered together.

What makes this option different

  • 3 mm optical path for UV/Vis methods designed around a shorter-than-standard path length.
  • Four-Way Light configuration for optical access on four sides of the cell body.
  • 1050 µL nominal capacity in a short-path screw-top cell.
  • M10 screw-cap neck with accompanying closure for direct top filling and covered handling.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Fill the chamber through the screw opening, then close and position the cell consistently for blank and sample measurements. Make sure the sample level covers the illuminated region, and remove visible bubbles before reading.

The screw-cap format is useful for routine filling and emptying, but the M10 thread should not be treated as a pressure-rated connection. If your method involves demanding liquids, long contact times or elevated temperature, review suitability for the full assembled cell before use.

First-use check

  1. Inspect the optical faces, chamber and closure seating area before first use.
  2. Place the cell in the holder with a suitable blank and verify beam alignment.
  3. After filling, clear bubbles and wipe exterior faces before measurement.

Fit and optical alignment

View the English selection reference.

The base dimensions are 12.5 × 5.5 mm, the optical body height is 38 mm, and the overall height with cap is 58 mm. Check holder width, insertion depth and top clearance for the neck and cap, because the assembled cell occupies more space than the optical body alone.

Z Height is not established for this SKU, so verify beam position against your instrument or holder before ordering. Four-Way Light describes the optical access category, but fit in your instrument still depends on the actual beam geometry and mounting arrangement.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is commonly selected for methods involving organic solvents or heated measurement conditions. For this assembled cell, suitability still depends on the actual liquid, concentration, temperature, contact time and the closure as well as the quartz body.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 Quartz Screw-Top Cuvette with accompanying closure. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for projects involving path length, chamber size, external envelope, optical windows, closure details and tolerances. Send your drawing or holder information, sample conditions and quantity if you need a modified version.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQSC007) Quartz Screw-Top Cuvette, 3 mm path, Large Screw Opening”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare