(MQQFC101) Quartz Counting Flow Cell, 0.25 mm path, Two Opposed Tube Connections
Description
MQQFC101 is a JGS1 quartz counting flow cell for UV/Vis setups that use a 0.25 mm optical path and a connected liquid circuit. Its flat body, two opposed tube connections and 20 × 20 × 0.25 mm internal region make it useful when you need a defined thin sample layer in a compact flow-cell format rather than an open-top cuvette.
This cell uses Standard 80 adhesive-bonded quartz construction and is specified for 200 to 2500 nm. The body dimensions and internal region are both relevant here, because holder space and illuminated sample area both matter when you are fitting a short-path cell into an existing optical setup.
- Path Length
- 0.25 mm
- Cell Type
- Counting Flow Cell
- Light Transmission Configuration
- Two-Way Light
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Counting Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 0.25 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 42 × 4.12 × 31.7 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 20 × 20 × 0.25 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 1.5 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Port Layout | End/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Counting Flow Cell |
Choose this option
Choose this flow cell when your method requires a fixed 0.25 mm path in a two-port flow format with light passing through two opposing faces. It suits installations where you want a flat quartz body with tubing access from opposite sides, and where the internal sample region must be checked against your beam footprint and mounting space.
What makes this option different
- 0.25 mm optical path for methods built around a very thin flowing sample layer.
- Two opposed tube connections for connecting the sample circuit from opposite sides.
- 20 × 20 × 0.25 mm internal region to compare with your illuminated sample area.
- 42 × 4.12 × 31.7 mm flat body for compact holder planning, with projecting tubes outside that body envelope.
Structure and dimensions

Using this cell
Install the cell with the optical faces aligned to the beam and support the body while making tubing connections. Fill and flush the liquid path slowly enough to clear trapped bubbles from the optical region before taking blank or sample readings.
Use the same mounting orientation and flow path for blank and sample measurements. Do not use the projecting tubes as handles, and set any pressure or flow limits according to the complete assembled circuit rather than assuming them from the cell body alone.
First-use check
- Inspect the optical faces, sample region and tube ends before installation.
- Check holder fit, beam alignment and tubing clearance before introducing sample.
- Prime the flow path with a suitable blank and confirm that bubbles have cleared from the optical area.
Fit and optical alignment
The body dimensions are 42 × 4.12 × 31.7 mm, and the internal dimensions are 20 × 20 × 0.25 mm. The stated outer dimensions apply to the body only, so leave additional space for the projecting tubes, connectors and bend radius on both sides.
Z Height is not specified for this item. If your holder or instrument has a fixed beam height, check that requirement before ordering. You can review the English reference drawing here: View the English selection reference.

Solvents and cleaning
Standard 80 uses an adhesive-bonded quartz construction and is suited to routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded assembly. If your method uses organic solvents or heated treatment, ask about a suitable alternative construction before ordering.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis, abrasive cleaners and cleaning methods that can stress the bonded assembly. Clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 Quartz Counting Flow Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review changes to path length, external envelope, optical windows, Z Height and connection details for related JGS1 quartz flow-cell projects. Send your drawing or holder details, sample conditions, tubing requirements and target quantity.
To discuss a custom version, please contact us and mention SKU MQQFC101.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.