(C0.12WS) Quartz Counting Flow Cell, 0.1 mm Path, 8 µL
Original price was: $195.00.$176.00Current price is: $176.00.
C0.12WS is a JGS1 quartz counting flow cell with a 0.1 mm optical path, Two-Way Light geometry and an 8 µL nominal cell volume. Its compact 30 × 15 × 4 mm body and opposed tube connections suit flow setups that need a very short path in a small mounting space. Standard 80 adhesive-bonded construction.
Description
C0.12WS is a JGS1 quartz counting flow cell built for flow measurements with a very short 0.1 mm optical path. It combines an 8 µL nominal cell volume with a compact 30 × 15 × 4 mm body and two opposed tube openings, which helps when you need a small optical cell body in a tightly arranged flow path. The quartz optical body supports UV to near-IR work within the stated 200–2500 nm range.
- Path Length
- 0.1 mm
- Sample Volume (Nominal)
- 8 µL
- Opening Configuration
- Two Tube Openings
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Counting Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 0.1 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 8 µL |
| External Dimensions | 30 × 15 × 4 mm |
| Cell Body Dimensions | 30 × 15 × 4 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 1.5 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Tube Openings |
Choose this option
Choose C0.12WS when your method needs the short path itself, not a larger chamber or a larger holder format. The two end connections support in-line sample routing through the cell, while the small body size helps when holder space is limited and you want the tubing to approach from opposite sides.
What makes this option different
- 0.1 mm optical path for methods that require a very short transmission path.
- 8 µL nominal volume in the cell body, helping you judge the sample region without treating tubing volume as part of the cell specification.
- Opposed tube connections with 1.5 mm OD and 1.0 mm ID tubes at the two ends of the cell body.
- Compact body dimensions of 30 × 15 × 4 mm, with these dimensions applying to the body only and not to the projecting tubes.
Using this cell
Mount the cell by supporting the body, not by loading the tube connections. After connecting your tubing, fill the cell gradually and watch the optical region for trapped bubbles before taking measurements.
The 8 µL figure is the nominal volume of the cell itself. It does not include connected tubing or the rest of the flow circuit, so plan your assembled system volume separately if that affects your method.
This is a Two-Way Light cell. Keep the optical faces clean, keep the cell orientation consistent between blank and sample runs, and confirm stable flow through the assembled setup before collecting data.
First-use check
- Inspect the optical faces and tube openings for dust, residue or shipping damage.
- Test the body fit in the holder and check tubing clearance before filling the cell.
- Run a suitable blank, remove any visible bubbles and confirm repeatable positioning in the optical path.
Fit and optical alignment
The stated 30 × 15 × 4 mm size describes the cell body only. Leave additional space for the projecting tubes, tubing bend radius, and hand access during installation and removal.
Z Height is not stated for this item. If your holder or instrument uses a fixed beam position, check the seated beam alignment in your fixture before ordering rather than relying on body size alone.
Solvents and cleaning
Standard 80 adhesive-bonded quartz is generally selected for routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded construction. If your method involves organic solvents or heated treatment, ask about a more suitable Sintered or Molded alternative.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
The listed price is for one C0.12WS flow cell.
Additional accessory contents should be confirmed for your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz flow-cell projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, sample conditions, quantity and target timing.
Discuss your requirements and quote part number C0.12WS.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.