(MQQFC110) JGS1 Quartz Counting Flow Cell, 0.2 mm Path, 16 µL
$186.00
JGS1 quartz counting flow cell with a 0.2 mm optical path and 16 µL nominal capacity in a 30 × 4 × 15 mm optical body. Two opposed tubes, sized at 1.5 mm OD / 1 mm ID, connect the small sample region to your flow circuit. Two opposing optical faces support transmission measurement. One cell supplied.
Description
MQQFC110 is a JGS1 quartz counting flow cell for UV/Vis setups that need a 0.2 mm optical path in a compact in-line body. Its 16 µL nominal capacity and two opposed fluid tubes help when you need to plan the optical path, sample region and tubing arrangement together as one installed assembly.
- Path Length
- 0.2 mm
- Sample Volume (Nominal)
- 16 µL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Counting Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 0.2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 16 µL |
| Cell Body Dimensions | 30 × 4 × 15 mm |
| Body Height | 15 mm |
| Base Dimensions | 30 × 4 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 1.5 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Opposed Fluid Tubes |
| Port Layout | End/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Counting Flow Cell |
Choose this option
Choose MQQFC110 when your method is based on a fixed 0.2 mm transmission path and you want a small integrated counting flow cell instead of an open chamber format. This option is useful when short-path measurement and compact tube-connected installation both matter in the same setup.
What makes this option different
- 0.2 mm optical path for methods that require a short fixed transmission length.
- 16 µL nominal capacity for planning the sample region within the flow circuit.
- Two-Way Light layout for straight-through optical measurement across the defined path.
- Two opposed fluid tubes with 1.5 mm outer diameter and 1 mm inner diameter for connection planning.
Using this cell
Install the cell with the quartz body properly supported and route the tubing so the two ends are not pulled out of alignment. Fill slowly, clear visible bubbles from the optical region and establish your blank after the circuit reaches stable conditions.
The 16 µL figure is the nominal cell volume, not a stated minimum working volume. If your method depends on the smallest usable fill, a defined pressure limit or a specific flow envelope, qualify those conditions on the complete assembled setup.
First-use check
- Inspect the optical faces and tube ends before installation.
- Verify holder fit and beam alignment with a suitable blank.
- Check that the optical region fills cleanly and remains free of visible bubbles before measurement.
Fit and optical alignment
View the English selection reference.
The stated 30 × 4 × 15 mm dimensions describe the optical body only. Allow extra installation space for the projecting tubes, any fittings you add and the bend radius of attached tubing.
Z Height is not stated for this SKU. If your holder or instrument has a fixed optical centerline, check beam-height compatibility separately before ordering.
Gallery series photographs illustrate the shared cell format. The ordered path length and nominal capacity are the values stated for MQQFC110.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction suited to routine room-temperature aqueous samples and buffers. Avoid organic sample solvents and organic cleaning agents with this bonded assembly. If your method involves organic solvents or heated treatment, ask about a more suitable construction before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 Quartz Counting Flow Cell. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to path length, body dimensions, optical layout, tube connections and other installation-related details. Send your drawing or holder information, sample conditions, required quantity and delivery target. Prototype batches typically involve 2–4 cells, with final feasibility, specifications, price and timing confirmed in quotation. Send a product-selection enquiry with SKU MQQFC110.
Additional information
| Weight | 50 g |
|---|