(MQQFL073) Glass Fluorescence Cuvette, 10 mm path, 3.5 mL nominal capacity, Flat-Base Version, Pack of 2
$48.00
Glass fluorescence cuvette for visible-light fluorescence and visible spectroscopy, with a 10 mm path length, Four-Way Light access and 3.5 mL nominal capacity per cell. This flat-bottom, open-top version uses a square 12.5 x 12.5 mm body format for upright holder layouts. Sold as a pack of 2 with accompanying closures.
Description
MQQFL073 is a glass fluorescence cuvette for visible-light fluorescence and visible spectroscopy, supplied here as a pack of 2. Each cell combines a 10 mm optical path, Four-Way Light access and 3.5 mL nominal capacity in an open-top, flat-bottom square format. This option is useful when you want two matching cells for routine sample and blank work while keeping the specified flat-bottom profile in the selected holder layout.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Visible-Light Fluorescence; Visible Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Glass |
| Closure Included | Yes |
| Opening Configuration | Open Top |
| Sales Unit | pack of 2 |
| Package Contents | 2 × Glass Fluorescence Cuvette; Accompanying closures |
Choose this option
Choose this cuvette when your method uses visible-range fluorescence or visible spectroscopy and you want a full-size 10 mm cell with optical access from four sides. The open top gives direct sample access for filling and rinsing, while the flat-bottom version keeps this specific body profile distinct from other base styles in the same general format.
What makes this option different
- 10 mm optical path suits full-size measurements in the selected beam direction.
- Four-Way Light configuration gives optical access on four sides for visible-light fluorescence and visible spectroscopy setups.
- Flat-bottom version keeps the specified base profile visible as a selection point, separate from path length and outer footprint.
- Open-top access allows direct filling, rinsing and drying without threaded fittings or a removable plate assembly.
- 3.5 mL nominal capacity per cell provides the stated sample volume for this standard-size body format.
- Pack of 2 is practical when you want two matching cells in one purchase.
Using this cell
Fill each cuvette from the open top and set the fill level so the illuminated region used by your instrument is fully covered during measurement. The 3.5 mL figure is the nominal capacity of each cell, not a minimum working volume.
For fluorescence work, keep the same orientation for blank and sample measurements if your method depends on a consistent viewing direction. Before reading, remove bubbles from the optical region and wipe off exterior droplets or fingerprints.
First-use check
- Inspect both cells for chips, residue or handling marks on the optical faces and chamber.
- Check that each cell seats squarely in your holder and can be inserted without top interference.
- Run a blank in the same orientation you plan to use for routine measurements.
Fit and optical alignment
View the English selection reference.
The stated outer size is 12.5 x 12.5 x 45 mm. Check holder width, depth and top clearance before ordering, especially if your compartment is close-fitting or access above the cell is limited.
Z Height is not available for this SKU, so the outside dimensions should not be treated as proof of beam-height compatibility. If your instrument uses a fixed beam position, compare with your current cuvette or send your holder details before ordering.

Solvents and cleaning
This is a glass cell with supplier-described fused-integrated construction. In practice, choose samples and cleaning liquids that are suitable for the complete cell and closure assembly, especially if your process involves aggressive chemicals, elevated temperatures or long soaking times.
Do not use hydrofluoric acid with glass. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with soft non-abrasive tissue or swabs.
General fabrication background is available here: MQ Cuvette Fabrication Glossary.
Included with this option
2 glass fluorescence cuvettes and accompanying closures. The listed price is for the pack of 2.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body size or holder-related geometry, contact us with the SKU, your current cell reference or holder drawing, application wavelength range and required quantity. Custom work is quoted separately from this listed glass pack option.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.











Reviews
There are no reviews yet.