(MQQFL066) Quartz High-Capacity Cuvette, 22 mm path, 7 mL nominal capacity, Square Chamber with Lid
$756.00
MQQFL066 is a JGS1 quartz high-capacity cuvette for UV/Vis work with a 22 mm optical path, Five-Way Light access and a supplied quartz lid. Its 7 mL nominal capacity suits methods that need a larger square sample chamber while keeping top access for direct filling. Sold as 1 piece with the accompanying closure.
Description
MQQFL066 is a JGS1 quartz high-capacity cuvette for UV/Vis methods built around a 22 mm optical path. It combines a square quartz body, Five-Way Light access and a removable quartz lid, giving you a larger nominal sample volume together with direct top access for filling and inspection. This is a useful choice when you want a covered square cell without moving to a flow assembly or a narrow low-volume format.
- Path Length
- 22 mm
- Sample Volume (Nominal)
- 7 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | High-Capacity Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 22 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 7 mL |
| External Dimensions | 26 × 26 × 22 mm |
| Body Height | 22 mm |
| Base Dimensions | 26 × 26 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | Quartz |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz High-Capacity Cuvette; Accompanying closure |
Choose this option
Choose MQQFL066 when your method calls for a 22 mm path and you want a larger square chamber with a matching quartz lid included. The 7 mL nominal capacity helps when your procedure needs a higher fill volume than a small cuvette body, while the open-top format still lets you load and check the sample directly before placing the cover.
What makes this option different
- 22 mm optical path for methods specified around this longer path length.
- Five-Way Light access for setups that use more than one optical face around the sample region.
- 7 mL nominal capacity in a square high-capacity chamber rather than a small cuvette format.
- Quartz lid included so the listed sale unit already includes the matching cover.
Using this cell
Fill the chamber from the open top and place the quartz lid after loading if your handling routine calls for a cover. Keep the cell orientation consistent between blank and sample measurements, especially if your setup uses more than one optical direction.
The stated 7 mL is a nominal chamber volume, not a minimum working fill. Set your actual liquid level so the illuminated region is covered in your instrument, and remove bubbles before measurement. Keep the outer optical faces free of droplets, fingerprints and residue.
First-use check
- Inspect the optical faces, rim and lid for chips, residue or handling marks.
- Place the cell in the holder and verify that the beam passes through the intended optical direction.
- Run a blank at the intended fill level and check for bubbles, exterior droplets and stable positioning.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The body footprint is 26 × 26 mm with a 22 mm body height. Check your holder opening, side clearance and beam position against this larger square format. Z Height is not listed for this SKU, so do not assume beam-center compatibility from the nominal volume or outside size alone.
The quartz lid is removable and sits over an open-top chamber. Leave enough clearance above the cell for lifting and replacing the cover during filling, sampling and cleaning. The lid should not be treated as a pressure-rated or gas-tight closure.

Solvents and cleaning
This cuvette is listed as Molded 83. This fabrication type is commonly selected for organic-solvent methods and applications that may involve heat, but solvent suitability still depends on the complete use conditions and the full wetted assembly.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces and lid gently with suitable non-abrasive lab wipes. If your process involves aggressive chemicals, elevated temperature or long contact time, please contact us with the liquid, concentration, temperature and exposure time.
Included with this option
1 quartz high-capacity cuvette and 1 accompanying closure. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for requirements involving optical path length, body size, sample volume, optical windows, Z Height, closure details and fabrication. If you need a different holder fit or top arrangement, send your drawing or existing cell reference through the contact page and include the critical dimensions, application wavelength range, sample conditions and target quantity.
Additional information
| Weight | 150 g |
|---|
You must be logged in to post a review.













Reviews
There are no reviews yet.