Site Navigation

(MQQFC090) Quartz Counting Flow Cell, 0.05 mm path, 1 µL nominal capacity, In-Line Counting Region

Weight50 g
SKU: MQQFC090

$528.00

In Stock

MQQFC090 is a JGS1 quartz counting flow cell with a 0.05 mm optical path, 1 µL nominal capacity and two opposed tube connections. This compact Two-Way Light format suits in-line UV/Vis flow setups that need a very short path in a small body. Sold as 1 piece. Standard 80.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC090 is a compact quartz counting flow cell for UV/Vis flow setups that need a very short 0.05 mm optical path. This JGS1 quartz cell combines a 1 µL nominal capacity with two opposed fluid tubes in a 30 × 8 × 8 mm body, making it useful when the measuring region must stay small while the cell is installed in line.

Path Length
0.05 mm
Sample Volume (Nominal)
1 µL
Opening Configuration
Two Opposed Fluid Tubes

Selection Specifications

Product KindFlow Cell
Cell TypeCounting Flow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length0.05 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1 µL
External Dimensions30 × 8 × 8 mm
External Dimensions ScopeBody Only
MaterialQuartz
Material GradeJGS1
Port Count2
Tube Outer Diameter (OD)1.5 mm
Tube Inner Diameter (ID)1 mm
Fabrication MethodStandard 80
Opening ConfigurationTwo Opposed Fluid Tubes
Port LayoutEnd/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original
Pack Quantity1 Piece
Package Contents1 × Quartz Counting Flow Cell

Choose this option

Choose MQQFC090 when your method is built around a very short fixed path and a small nominal sample region in an in-line format. The opposed tube layout keeps the fluid connection straightforward, while the compact body helps when the holder space around the quartz block is limited and the tubing can be routed separately.

What makes this option different

  • 0.05 mm optical path for methods that require a very short fixed path length.
  • 1 µL nominal capacity in a compact flow-cell format.
  • Two-Way Light layout for transmission along the intended optical axis.
  • Two opposed tube connections with 1.5 mm OD and 1 mm ID for in-line plumbing.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Mount and support the quartz body first, then connect the tubing without using the projecting tubes as handles. Fill slowly so the sample wets the measurement region evenly, and inspect the optical area carefully for bubbles before measurement.

The 1 µL figure is the nominal cell volume, not a stated minimum working volume. For routine use, prepare the blank under the same installed circuit conditions and keep the cell orientation and connection layout consistent between blank and sample runs.

No pressure rating is stated for this cell. Review the operating pressure of your system before using it in a pressurized line.

First-use check

  1. Inspect the optical faces, sample region and tube ends before connecting the circuit.
  2. Test holder seating and optical alignment with a suitable blank.
  3. After filling, remove visible bubbles and repeat the blank in the same installed position.

Fit and optical alignment

View the English selection reference.

The stated 30 × 8 × 8 mm dimensions apply to the quartz body only. They do not include the extra length of the two tube connections, so check total installed clearance for tubing bends and holder access before ordering.

This is a Two-Way Light cell, so align the measuring beam with the intended transmission faces. Z Height is not listed for this item, so beam-center compatibility should be checked against your instrument or holder if your setup uses a fixed beam height.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses Standard 80 adhesive-bonded quartz construction. It is suited to routine room-temperature aqueous samples and buffers.

Avoid organic samples and organic cleaning solvents such as acetone, methanol and DMSO with this bonded assembly. If your method involves organic solvents or heated treatment, ask about a more suitable Sintered or Molded alternative before ordering.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the exterior optical faces gently with non-abrasive optical tissue.

Included with this option

1 Quartz Counting Flow Cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with your holder details, sample conditions and required quantity.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC090) Quartz Counting Flow Cell, 0.05 mm path, 1 µL nominal capacity, In-Line Counting Region”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare