(MQQST004) Quartz Cuvette, 3 mm Path, 1.05 mL, Size 14 Ground Joint
Description
MQQST004 is a JGS1 quartz cuvette with a size 14 ground-joint opening for UV/Vis spectroscopy with a 3 mm optical path, a Two-Way Light layout and 1.05 mL nominal capacity. It is a practical choice when you need a 3 mm transmission path and want a ground-joint opening for top access. This listing is sold as 1 piece.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 1.05 mL
- Opening Configuration
- Ground Joint, size 14 (supplier designation)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 5.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Ground Joint, size 14 (supplier designation) |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Stoppered Cuvette |
Choose this option
Choose MQQST004 when your method is set up for a 3 mm transmission path and a compact rectangular cell body. The size 14 ground-joint opening is part of the selection value here: it affects how you fill the cell, what clearance you need above it, and which mating joint dimensions must be checked. Its stated nominal capacity helps you judge the scale of the sample region without treating that figure as the minimum working fill.
What makes this option different
- 3 mm optical path for UV/Vis methods that use the specified 3 mm transmission path.
- Two-Way Light configuration for measurement through two opposing optical faces.
- Size 14 ground-joint opening for top access and compatibility checks with joint-based filling or handling arrangements.
- 1.05 mL nominal capacity to indicate the cell scale for sample planning.
- JGS1 quartz, 200 to 2500 nm for UV/Vis work across the stated wavelength range.
- Molded 83 fabrication for a quartz cell style commonly chosen for methods that may involve organic-solvent cleaning or temperature-related use, subject to the actual chemical conditions.
Using this cell
Fill the cuvette so the sample fully covers the illuminated region, then place it with the optical faces aligned to the instrument beam. Keep blank and sample in the same orientation, especially when working with a short-path cell where beam position matters.
The nominal capacity is 1.05 mL, but the minimum working volume is not established here. Use your beam height and fill level together when planning the actual sample volume for measurement.
First-use check
- Inspect the optical faces and the ground-joint opening for chips, residue or handling marks.
- Place the cell in the holder and run a blank to confirm beam alignment.
- After filling, remove bubbles and exterior droplets before measurement.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The optical cell body is 45 mm high with a 12.5 × 5.5 mm base. The extended neck raises the height to the joint top to 95 mm. Use the body dimensions for holder seating and the full 95 mm height for compartment clearance, with extra room for loading or a mating component. Z Height is not established for this exact SKU, so beam-center alignment still needs to be checked against your instrument.
Size 14 is the stated joint designation; it does not establish a full taper ratio, joint length or compatibility with every size 14 part. Match the mating geometry before use. No leak-tightness or pressure rating is specified.

Solvents and cleaning
This cell uses Molded 83 construction, often selected for organic-solvent methods. Suitability depends on the liquid, concentration, temperature and contact time for the complete assembly.
The chemical limits for this exact SKU are not established here. If your method uses aggressive chemicals, elevated temperature or long contact times, check the specific liquid, concentration, temperature and exposure time for this cell format before use. Do not use hydrofluoric acid on quartz, avoid hot strong alkalis, and clean the optical faces with non-abrasive materials.
Included with this option
The listed unit is one quartz cuvette with a size 14 ground-joint opening. If you require a separate stopper or mating component, specify it before ordering so the complete assembly can be confirmed.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, opening format, body envelope or other fit detail, please send your drawing or current cell reference. Send a product-selection enquiry with SKU MQQST004, holder details, sample conditions, quantity and destination.
We coordinate custom JGS1 quartz production. Prototype batches typically involve 2–4 cells; feasibility, final specifications, quantity, price and production time are confirmed in the project quotation.
Design notes for this configuration: Long-Neck Quartz Cuvette: Allowing Room for the Ground-Joint Closure
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.











Reviews
There are no reviews yet.